www.mdcusa.com
Ph: 833 632 8721
72
Read the following BEFORE proceeding
•
During the initial firing of the Furnace, a burn-off of excess paint and oils remaining from the
manufacturing process may cause “smoking” for 5 – 10 minutes.
•
The Furnace is equipped with a power switch. Gas will not flow to the burner and the Furnace
will not operate with the switch in the OFF position.
o
Door models have a power switch located inside of the door.
o
Non-door models (LD or Small Vent) have a power switch on the outside of the Furnace.
NOTICE
A. Turning On The Furnace
• Turn the thermostat to the lowest setting.
• Turn OFF all power to the Furnace at the main power supply.
• At the exterior access panel, turn the switch on the Furnace to the OFF position.
• Wait five minutes, then check for a gas odor.
• If a gas odor exists around the Furnace or floor area, follow the instructions in the warning box on the cover
page.
• If no gas odor is present, proceed to the next step.
• At the exterior access panel, turn the switch on the Furnace to the ON position.
• Turn ON the main power supply.
• Set the thermostat to the desired temperature.
If the Furnace will not operate, follow the instructions for “B. Turning Off The
Furnace” and call a qualified service technician.
NOTICE