www.mdcusa.com
Ph: 833 632 8721
56
Switching OFF the appliance
1. AquaGo comfort / AquaGo comfort plus
Set the control panel to “Off”.
2. Open the access door (refer to “Opening the access door” on page 51).
3. Switch off the appliance at the POWER switch (Fig. 8).
- The green Power-ON LED 1 (Fig. 8) extinguishes.
4. Close the access door (refer to “Closing the access door” on page 52).
5. If the appliance is not needed, turn off the gas supply to the appliance.
If you intend to put the RV into storage or turn off the appliance during freezing temperatures, refer to “Winterizing” on
page 58.
Operation in frost conditions
(Ambient temperatures below 39 °F (4 °C))
Risk of damage in frost conditions.
In frost conditions, ambient temperatures below 39 °F (4 °C), there is a risk that water in pipes, faucets and
appliances could freeze. This can cause considerable damage.
• If the appliance is not to be used in frost conditions, you must winterize the appliance. Refer to “Winterizing” on
page 58.
• Winter operation will not protect the RV’s entire water system. Water lines, faucets, water tanks and the
external water valves and the vehicle must be heated separately.
• The RV must be designed for winter use/freezing conditions.
• The water pipes in the RV must be ice-free to operate the AquaGo comfort / AquaGo comfort plus in winter.
Otherwise, there is no water flow and the appliance does not start
NOTICE
Only AquaGo basic
•
Never operate the AquaGo basic in frost conditions, this model must be winterized (refer to “Win-
terizing” on page 58).
Only AquaGo comfort / AquaGo comfort plus
When the vehicle is standing, to -4 °F (-20 °C)
• The appliance has a built-in thermostat that will start the burner and the circulation pump whenever the temperature
in the appliance falls below 41 °F (+5 °C). The burner will automatically shut off when it senses a temperature above 111
°F (44 °C).
•
For the appliance to operate properly, you must ensure a constant supply of power (12 V), propane
gas, sufficient water in the system. You must leave the appliance powered “ON”. The operating mode must be “ECO” or
“COMFORT”. The water system must be bled so that the circulation pump works.
• If the vehicle is standing and ambient temperatures are below -4 °F (-20 °C), the appliance must not be operated and
must be winterized. To winterize the appliance refer to “Winterizing” on page 58.
While driving (or if there is no gas supply), to -4 °F (-20 °C)