www.mdcusa.com
Ph: 833 632 8721
58
Winterizing AquaGo comfort plus
1. Close valves A, B and E.
2. Make sure that valve D remains in the closed position.
3. Open valve C.
4. Drain the appliance (“Draining the water and cleaning the water inlet filter” on page 60).
5. Flush the RV’s water system with a suitable winterizing fluid according to the supplier’s or RV manufacturer’s guide
-
lines.
6. Close all faucets (if open).
7. Open valve D.
8. Wait until winterizing fluid has drained. Collect escaping fluid in a suitable vessel.
9. Close valve D.
Maintenance
Repairs must be performed by a certified service technician. Truma recommends that the appliance be serviced annually
by a certified service technician. Verify proper operation after servicing.
High temperatures or repair attempts while the gas supply is turned on may result
in scalding injuries!
• Turn OFF the electrical power supply and the LP gas supply before starting
maintenance and repair work.
• Allow the appliance to cool down.
• Never actuate the pressure relief valve as long as the appliance is still hot.
WARNING
Injuries caused by the Easy Drain Lever!
• Never actuate the Easy Drain Lever as long as the appliance is under water
pressure and/or is still hot.
CAUTION
Sharp edges can cause cuts and injury!
• Always wear protective gloves to avoid injuries from sharp edges during
maintenance work.
CAUTION
Draining the water and cleaning the water inlet filter
To keep the appliance fully functional, clean the water inlet filter at least once a year.
1. AquaGo comfort / AquaGo comfort plus
2. Set the control panel to “Off”.
3. Remove the access door (refer to “Removing the access door” on page 52).
4. Switch OFF the appliance at the POWER switch.
5. Open all hot water faucets and wait for cold water. This will ensure that hot water is removed from the appliance
before draining.
6. Turn OFF the water supply or switch OFF the water pump.