65
HEATING (R407C)
MODEL : MDB400DR4 vs. M4MC100DR x 4
Indoor WB
Outdoor DB, °C
°C
19.4
25
30
35
40
46
50
52
54
13.9
34,780
37,488
39,907
42,325
44,743
47,645
49,579
50,547
51,514
15
34,855
37,793
40,417
43,040
45,664
48,812
50,911
51,960
53,010
16.7
35,095
38,377
41,308
44,238
47,169
50,685
53,029
54,202
55,374
18
35,278
38,824
41,989
45,154
48,319
52,117
54,650
55,916
57,182
19.4
35,476
38,012
40,276
42,540
45,738
49,576
52,135
53,414
54,693
20
35,561
39,333
42,701
46,069
49,438
53,479
56,174
57,521
58,868
22
35,843
39,429
42,631
45,833
49,035
52,877
55,439
56,720
58,000
22.2
35,871
39,439
42,624
45,809
48,995
52,817
55,365
56,639
57,913
24
36,159
39,562
42,601
45,639
48,678
52,324
54,755
55,970
57,186
MODEL : MDB500DR4 vs. M4MC125DR x 4
Indoor WB
Outdoor DB, °C
°C
19.4
25
30
35
40
46
50
52
54
13.9
44,660
47,005
49,099
51,192
53,286
55,798
57,473
58,311
59,148
15
43,067
46,788
50,109
53,431
56,753
60,739
63,396
64,725
66,053
16.7
43,574
47,337
50,697
54,058
57,418
61,450
64,138
65,482
66,827
18
43,961
47,757
51,147
54,537
57,926
61,994
64,706
66,062
67,418
19.4
44,377
46,331
48,076
49,820
55,402
62,100
66,565
68,798
71,031
20
44,556
48,450
51,927
55,403
58,880
63,052
65,833
67,224
68,615
22
45,152
49,251
52,912
56,572
60,233
64,625
67,554
69,018
70,482
22.2
45,211
49,331
53,010
56,689
60,368
64,783
67,726
69,197
70,669
24
42,347
46,333
49,891
53,450
57,008
61,279
64,125
65,549
66,972
All power units in watts
Summary of Contents for M4MC075D
Page 71: ...70 Blower Performance Curves BLOWER PERFORMANCE CURVE MDB 075D...
Page 72: ...71 BLOWER PERFORMANCE CURVE MDB 100D...
Page 73: ...72 BLOWER PERFORMANCE CURVE MDB 125D...
Page 74: ...73 BLOWER PERFORMANCE CURVE MDB 150D...
Page 75: ...74 BLOWER PERFORMANCE CURVE MDB 200D...
Page 76: ...75 BLOWER PERFORMANCE CURVE MDB 250D L s 70 65 60...
Page 77: ...76 BLOWER PERFORMANCE CURVE MDB 300D...
Page 78: ...77 BLOWER PERFORMANCE CURVE MDB 400D...
Page 79: ...78 BLOWER PERFORMANCE CURVE MDB 500D...
Page 80: ...79 BLOWER PERFORMANCE CURVE MDB 075D DR VERY HIGH STATIC...
Page 81: ...80 BLOWER PERFORMANCE CURVE MDB 100D DR VERY HIGH STATIC...
Page 82: ...81 BLOWER PERFORMANCE CURVE MDB 125D DR VERY HIGH STATIC...
Page 83: ...82 BLOWER PERFORMANCE CURVE MDB 150D DR VERY HIGH STATIC...
Page 89: ...88 MODEL MDB 500D4 DR4 NOTE 1 WITH SEQUENTIAL CONTROLLER 2 VERTICAL AIR DISCHARGE...
Page 90: ...89 Outlines And Dimensions Outdoor MODEL MMC 075 100D DR MODEL MDB 125D DR...
Page 91: ...90 MODEL MMC 150D DR OUTDOOR UNIT WITH BALL VALVE MODEL MMC 075D...
Page 92: ...91 MODEL MMC 100D MODEL MMC 125D...
Page 93: ...92 MODEL MMC 150D...
Page 97: ...96 MODEL MDB 400D4 vs MMC 100D x 4 MDB 500D4 vs MMC 125D x 4 WITH SEQUENTIAL CONTROLLER...
Page 101: ...100 MODEL MDB 400DR4 vs MMC 100DR x 4 MDB 500DR4 vs MMC 125DR x 4 WITH SEQUENTIAL CONTROLLER...
Page 102: ...101 Refrigerant Circuit Diagram MODEL MMC 075D 100D 125D 150D...
Page 103: ...102 MODEL MLC 061C...
Page 104: ...103 MODEL MMC 075DR 100DR 125DR 150DR R22 M4MC 75DR 100DR 125DR 150DR R407C...
Page 177: ...2004 McQuay International 1 800 432 1342 www mcquay com ISO 9002 REGISTERED...