Operation
ELECTRICAL CONNECTION
Wiring regulations about wire diameter differs from country to country. Please refer to your LOCAL
ELECTRICAL CODES for field wiring rules. Be sure that installation comply with such rules and regulations.
GENERAL PRECAUTION
Ensure that the rated voltage of the unit correspond to the name plate before carrying out proper wiring
according to the wiring diagram.
Provide a power outlet to be used exclusively for each unit. A power supply disconnect and a circuit breaker
for over-current protection should be provided in the exclusive line.
The unit must be GROUNDED to prevent possible hazard due to insulation failures
Every wiring must be firmly connected.
Every wiring should not touch the refrigerant piping, compressor and any moving parts of fan motor.
OPERATIONAL CHECK
After all wiring is completed and the system is charged with refrigerant, make sure the unit is operating
properly. Check that :-
Condenser fans are running with warm air blowing off the condensing unit.
Evaporator blowers are running and discharging cool air from ducts.
Suction line and liquid line pressures are in the region of 75 psig and 275 psig respectively.
SEQUENTIAL CONTROLLER BLOCK DIAGRAM
(OPTIONAL)
(OPTIONAL)
Summary of Contents for M4MC075D
Page 71: ...70 Blower Performance Curves BLOWER PERFORMANCE CURVE MDB 075D...
Page 72: ...71 BLOWER PERFORMANCE CURVE MDB 100D...
Page 73: ...72 BLOWER PERFORMANCE CURVE MDB 125D...
Page 74: ...73 BLOWER PERFORMANCE CURVE MDB 150D...
Page 75: ...74 BLOWER PERFORMANCE CURVE MDB 200D...
Page 76: ...75 BLOWER PERFORMANCE CURVE MDB 250D L s 70 65 60...
Page 77: ...76 BLOWER PERFORMANCE CURVE MDB 300D...
Page 78: ...77 BLOWER PERFORMANCE CURVE MDB 400D...
Page 79: ...78 BLOWER PERFORMANCE CURVE MDB 500D...
Page 80: ...79 BLOWER PERFORMANCE CURVE MDB 075D DR VERY HIGH STATIC...
Page 81: ...80 BLOWER PERFORMANCE CURVE MDB 100D DR VERY HIGH STATIC...
Page 82: ...81 BLOWER PERFORMANCE CURVE MDB 125D DR VERY HIGH STATIC...
Page 83: ...82 BLOWER PERFORMANCE CURVE MDB 150D DR VERY HIGH STATIC...
Page 89: ...88 MODEL MDB 500D4 DR4 NOTE 1 WITH SEQUENTIAL CONTROLLER 2 VERTICAL AIR DISCHARGE...
Page 90: ...89 Outlines And Dimensions Outdoor MODEL MMC 075 100D DR MODEL MDB 125D DR...
Page 91: ...90 MODEL MMC 150D DR OUTDOOR UNIT WITH BALL VALVE MODEL MMC 075D...
Page 92: ...91 MODEL MMC 100D MODEL MMC 125D...
Page 93: ...92 MODEL MMC 150D...
Page 97: ...96 MODEL MDB 400D4 vs MMC 100D x 4 MDB 500D4 vs MMC 125D x 4 WITH SEQUENTIAL CONTROLLER...
Page 101: ...100 MODEL MDB 400DR4 vs MMC 100DR x 4 MDB 500DR4 vs MMC 125DR x 4 WITH SEQUENTIAL CONTROLLER...
Page 102: ...101 Refrigerant Circuit Diagram MODEL MMC 075D 100D 125D 150D...
Page 103: ...102 MODEL MLC 061C...
Page 104: ...103 MODEL MMC 075DR 100DR 125DR 150DR R22 M4MC 75DR 100DR 125DR 150DR R407C...
Page 177: ...2004 McQuay International 1 800 432 1342 www mcquay com ISO 9002 REGISTERED...