65
© 2010 McNeilus Truck and Manufacturing, Inc.
Zero Radius Side Loader
Operation
4.3
Water Tank
4.3.1
Water Tank Safety
WARNING
IMPORTANT ALUMINUM AND STEEL WATER
TANK INFORMATION.
1. Inspect water tank on a daily basis for
any damage including, but not limited to,
dents, gouges in metal, or leaks.
2. Do not weld on or repair water tank.
Instead, replace water tank with a new
OEM water tank.
3. Never pressure test an empty water tank.
Only pressure test a full water tank.
4. Never remove pressure regulator or pressure
safety valve from tank.
• If regulator or safety valve is defective, it must
be replaced before Packer is put into service.
5. Do not pressurize water tank beyond its
working pressure.
• If pressure exceeds the working pressure,
immediately depressurize water tank and
replace pressure regulator and pressure safety
valve.
WARNING
CONTINUED
6. Never drive the truck with the water tank
pressurized.
• Depressurize water tank prior to transit to or
from job site.
• Water tank should be pressurized only when
being used.
7. Never modify water tank in any way.
8. Immediately replace safety decals with
McNeilus decals if decals are missing or
difficult to read.
9. Refer to the McNeilus Operator’s Manual or
contact McNeilus at 1-888-686-7278 if you have
questions or require assistance.
4.3.2
Introduction
Your refuse vehicle may be equipped with a pressurized
water tank. This tank is used to rinse debris off the refuse
vehicle. Air pressure from the truck’s brake system is used to
provide pressure to the tank. Use these instructions for the
safe operation and inspection of all McNeilus, Oshkosh, and
London pressurized water tanks.
If your refuse vehicle is equipped with a non-pressurized water
tank (a system that uses a water pump to provide pressure),
refer to the instructions provided with the refuse vehicle.