63
8.7
Cleaning System Status Parameters
Cleaning system status registers.
Sr. No
Parameter
Register Address
Type
Read/ Write
1
Cleaning System Status
b0: Cleaning System
Power Status
b1: Water Level Low
b2: Water Level High
b3: Pump Status
b4: Valve Clean Panel
b5: Valve Soiled Panel
b6: Reference Panel
clean ON
b7: Soiled Panel clean
ON
10663
16 bits Unsigned
Integer
Read only
2
Cleaning Cycle Number
10664
16 bits Unsigned
Integer
Read only
3
Pump ON Remain Time
10665
16 bits Unsigned
Integer
Read only
4
Pump OFF Remain
Time (sec)
10666
16 bits Unsigned
Integer
Read only
Table-8.7: Cleaning system status parameters