16
These parameters can be changed via the embedded web server.
3.4.4 Port ETH
This ETH port (base 10MHz) is multi- function port.
Figure-3.4.4.1: Soiling station ETH Port.
Use standard LAN cable with RJ 45 connector for connecting to the port.
Port activity LED are provided on the connector.
This port is used for following operations:
i)
Configuration of soiling station via embedded web server.
ii)
Downloading logged file.
iii)
MODBUS TCP slave (multiple masters) to provide measured and collected
parameters to other devices and SCADA.
iv)
SNTP Client for time synchronization.
v)
File transfer client (ftp).
Configuration details for ETH port are provided
Default network configuration for the ETH port is provided in table 3.4.4 below.
Table-3.4.4: Default ETH port network configuration
These parameters can be changed via the embedded web server.
Procedure for setting default IP address in the soiling station is provided below. This
procedure should be followed only if IP address of the soiling station is not known. If
S. No.
Description
Value
1
Device IP
192.168.100.222
2
Network Mask
255.255.255.0
3
Network Gateway IP
0.0.0.0
4
Primary DNP IP
8.8.8.8
5
Secondary DNS IP
8.8.4.4