6
SPECIFICATIONS
NOTES:
1. All 265V models must use Amana
®
brand’s subbase (PTSB4**C) or Amana
®
brand’s hard wire kit (PTPWHWK4).
2. Minimum branch circuit ampacity rating conform to the National Electric Code. However, local codes should apply.
3. Minimum voltage on 230/208 volt models is 197 volts; maximum is 253 volts. Minimum voltage on 265 volt models is 238.5 volts; maximum is 291.5
volts.
4. Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265 volt models must be cartridge-style time
delay fuses (included and factory installed on Amana
®
brand chassis).
5. Heating capacity and efficiency are based on unit operation without condensate pump. Unit automatically switches to electric heat at 25°F
outdoor coil temperature.
6. Total watts for 15,000 Btuh models; subtract 30 watts for PT12*A**AA and 70 watts for PT07/09*A**AA.
7. Please specify 2-digit heater kW size to complete model number.
8. Total amps for 12,000 and 15,000 Btuh models; subtract 0.2 amps for PT07/09*A*AA.
PTH073A**AA
PTH074A**AA
PTH093A**AA
PTH094A**AA
PTH123A**AA
PTH124A**AA
PTH153A**AA
PTH154A**AA
Voltage
1&3
230/208
265
230/208
265
230/208
265
230/208
265
Capacity (BUTH)
7,400/7,200
7,400
9,000/8,800
9,000
12,000/11,600
12,000
14,000/13,800
14,000
Amps
2.5/2.6
2.0
3.5/3.8
3.0
4.6/5.0
3.7
7.4/7.9
6.5
Watts
625/610
625
810/790
810
1,145/1,125
1,145
1,490/1,470
1490
EER
11.5
11.5
11.1
11.1
10.6
10.6
9.4
9.4
UNIT WITHOUT
ELECTRIC HEATER
Minimum Circuit Ampacity
2&4
4.0
3.3
4.8
4.1
7.3
5.7
8.4
7.7
CFM
HIGH
220/215
220
220/215
220
290/270
290
325/315
325
LOW
175/155
175
175/155
175
220/190
220
250/220
250
HIGH
235/230
235
235/230
235
310/290
310
345/335
345
LOW
185/165
185
185/165
185
235/205
235
265/235
265
35
35
35
35
45
45
50
50
Dehumidification
(pints/hr)
1.9
1.9
2.7
2.7
3.8
3.8
4.4
4.4
Net Weight
110
110
120
120
130
130
140
140
Shipping Weight (approx.
lbs.)
130
130
140
140
150
150
160
160
Cool, Wet Coil
COOLING DATA (HEAT PUMP)
Ventilated Air
Dry Coil
PTC073A**AA
PTC074A**AA
PTC093A**AA
PTC094A**AA
PTC123A**AA
PTC124A**AA
PTC153A**AA
PTC154A**AA
Voltage
1&3
230/208
265
230/208
265
230/208
265
230/208
265
Capacity (BUTH)
7,500/7,400
7,500
9,000/8,800
9,000
12,200/12,000
12,200
14,200/14,000
14,200
Amps
2.5/2.6
2.0
3.5/3.8
3.0
4.6/5.0
3.7
7.4/7.9
6.5
Watts
625/610
625
810/790
810
1,145/1,125
1,145
1,510/1,490
1,510
EER
11.6
11.6
11.1
11.1
10.8
10.8
9.4
9.4
UNIT WITHOUT
ELECTRIC HEATER
Minimum Circuit Ampacity
2&4
4.0
3.3
4.8
4.1
7.3
5.7
8.4
7.7
CFM
HIGH
220/215
220
220/215
220
290/270
290
325/315
325
LOW
175/155
175
175/155
175
220/190
220
250/220
250
HIGH
235/230
235
235/230
235
310/290
310
345/335
345
LOW
185/165
185
185/165
185
235/205
235
265/235
265
35
35
35
35
45
45
50
50
Dehumidification
(pints/hr)
1.9
1.9
2.7
2.7
3.8
3.8
4.4
4.4
Net Weight
110
110
120
120
130
130
140
140
Shipping Weight (approx.
lbs.)
130
130
140
140
150
150
160
160
Cool, Wet Coil
COOLING DATA (COOLING with ELECTRIC HEAT)
Ventilated Air
Dry Coil
EER -
Energy Efficiency Ratio per The Air-Conditioning,
Heating, and Refrigeration Institute (AHRI) Test
Procedures and Canadian Standards Association
(CSA) Test Procedures
COP -
Coefficient of Performance per AHRI Test
Procedures