10
SPECIFICATIONS
NOTES:
1. All 265V models must use Amana
®
brand’s subbase (PTSB4**E) or an Amana
®
brand hard wire kit (PTPWHWK4).
2. Minimum branch circuit ampacity ratings conform to the National Electric Code. However, local codes should apply.
3. Minimum voltage on 230/208 volt models is 197 volts; maximum is 253 volts. Minimum voltage on 265 volt models is 238.5 volts; maximum is 291.5 volts.
4. Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265 volt models must be cartridge-style time delay fuses (included
and factory installed on Amana
®
brand all 265 volt chassis).
5. Heating capacity and efficiency are based on unit operation without condensate pump. Unit automatically switches to electric heat at approximately 24°F outdoor ambient.
6. Total watts for 12,000 and 15,000 Btuh models. Subtract 70 watts for PT07/09*B*AE.
7. Please specify 2-digit heater kW size to complete model number.
9. Refrigerant used in all systems is R-22.
8. Total amps for 12,000 and 15,000 Btuh models; subtract 0.2 amps for PT07/09*B*AE.
10. All units meet or exceed ASHRAE 90.1 standards.
11. Some units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meeat UL 484 standards.
12. Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
230V
208V
265V
230/208
2 .5/2.0
1
8 ,500
6,80 0
---
2,650/2,140 11.6/10.5
14.5
15
6 - 15 P
230/208
3 .5/2.9
1
12,000
9,90 0
---
3,650/3,040 15.9/14.5
19.9
20
6 - 20 P
230/208
5 .0/4.1
1*
17,100 14,000
---
5,150/4,240 22.4/20.4
28.1
30
6 -30 P
265
2.5
1
---
---
8,500
2,650
10.1
12.7
15
7 - 20 P
265
3.7
1
---
---
12,600
3,850
14.7
18.3
20
7 - 20 P
265
5.0
1*
---
---
17 ,100
5,150
19.6
24.5
25
7 - 30 P
* PTH/PTC09*B50*G/K have the same airflow as a PTC/PTH12*B***G (not available on 7,000 BTU/h models).
HEAT PERFORMANCE (ELECTRIC HEAT) ELECTRIC DATA
(ALL BTUH SIZES, ALL MODELS)
Nomina l Heating
(BTUH)
Number
of
Stages
Electric Heater Size
(kW)
Voltage
Total
Watts
Total
Amps
Minimum
Ampacity
1
Overcurrent
Protection
5
Power
Cord
1
PTH073B***
E - Y
PTH074B***
E - Y
PTH093B***
E - Y
PTH094B***
E - Y
PTH123B***
E - Y
PTH124B***
E - Y
PTH153B***
E - Y
PTH154B***
E - Y
6,200/6,00
6200
8,200/8,000
8200
10,800/1 0,600
10800
13,300/13,200
1 3,300
2.6/3.0
2.2
3.2/3.6
2.6
4.5/5 .1
3.9
5.7/6.3
5.4
550/530
550
750/73 0
750
102 0/1,000
1020
1,340/1,330
1,340
3.3
3.3
3.2
3.2
3.1
3.1
2.9
2.9
235/230
235
235/23 0
230
310/2 90
310
345/335
345
Outdoor
Ambient
ºF
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
62
7,200/7,000
7,200
9,800/9,600
9,800
13,000/1 2,800
13,000
15,800/15,700
1 5,800
57
6,900/6,700
6,900
9,300/9,100
9,300
12,300/1 2,100
12,300
15,000/14,900
1 5,000
52
6,500/6,300
6,500
8,700/8,500
8,700
11,600/1 1,400
11,600
14,200/14,100
1 4,200
47
6,200/6,000
6,200
8200/8,000
8,200
10,800/1 0,600
10,800
13,300/13,200
1 3,300
Rating
Point
(COP)
3.3/3.3
3.3
3.2/3.2
3.2
3.1/3.1
3.1
2.9/2.9
2.9
452
5,900/5,700
5,900
7,700/7,500
7,700
10,100/9,900
10,100
12,500/12,400
1 2,500
37
5,600/5,400
5,500
7,200/7,00
7,200
9,400/9 ,200
9,4 00
11,700/11,600
1 1,700
32
5,300/5,100
5,200
6,700/6,500
6,700
7,900/7 ,700
7,9 00
10,00 0/9,900
1 0,000
Outdoor
Ambient
ºF
Watts
Watts
Watts
Watts
Watts
Watts
Watts
Watts
62
580/560
580
810/79 0
810
1,120/1 ,100
1,1 20
1,465/1,455
1,465
57
575/555
575
800/78 0
800
1,090/1 ,075
1,0 90
1,440/1,430
1,440
52
555/535
555
775/75 5
775
1,060/1 ,045
1,0 60
1,405/1,395
1,405
47
550/530
550
750/73 0
750
1,020/1 ,005
1,0 20
1,340/1,330
1,340
42
540/525
560
730/71 0
730
985/9 70
985
1,325/1,315
1,325
37
530/515
545
705/68 5
705
950/9 35
950
1,285/1,275
1,285
32
515/500
535
690/67 0
690
900/8 85
900
1,240/1,230
1,190
HEATING PERFORMANCE - REVERSE CYCLE
BTUH
5
COP
5
CFM (Dry)
Heating Capacity
Reverse Cycle
1& 7
Amps
12