SPECIFICATIONS
PTH********[M/R/Z]
- Denotes M or N Models
*Approximately 95 CFM with optional power vent kit.
Actual vent CFM performance will vary due to application and installation conditions.
NOTES:
1. All 265V models must use Amana
®
brand’s subbase (PTSB4**E) or an Amana
®
brand hard wire kit (PTPWHWK4).
2. Minimum circuit ampacity ratings conform to the National Electric Code. However, local codes should apply.
Minimum voltage on 230/208 volt models is 197 volts; maximum is 253 volts.
3. Minimum voltage on 265 volt models is 238.5 volts; maximum is 291.5 volts.
4. Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265 volt models must be cartridge-style time delay fuses
(included and factory installed on Amana
®
brand all 265 volt chassis). See heater performance for total MCA.
5. Heating capacity and efficiency are based on unit operation without condensate pump. Unit automatically switches to electric heat at approximately 24°F outdoor ambient.
6. Total watts for 12,000 and 15,000 Btuh models. Subtract 70 watts for PT07/09
7. Please specify 2-digit heater kW size to complete model serial number.
8. Total amps for 12,000 and 15,000 Btuh models; subtract 0.2 amps for PT07/09
9. Refrigerant used in all systems is R-22.
10. All units meet or exceed ASHRAE 90.1 standards..
11. All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
12. Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor models only.
Model
1, 7, 9, 10, 12
PTH
073D***[R/Z]
PTH
093D**AR
PTH
123C**AM
PTH
123D**AR
PTH
094D****
PTH
124C**AM
Voltage
1, 3, 12
230 / 208
230 / 208
230 / 208
230 / 208
265
230 / 208
Capacity (BUTH)
7,000/6,800
9,000/8,800
11,500/11,200
11,700/11,500
9,100
11,300
Amps
3.5/3.5
4.4/4.4
4.8/5.2
5.4/5.4
3.6
4.7
Watts
605/585
795/775
1,085/1,060
1,115/1,095
805
1,070
EER
11.3/11.8
11.3
10.6
10.5
11.3
10.6
UNIT WITHOUT
ELECTRIC HEATER
Minimum Circuit Ampacity
2 , 4 , 12
4.2
5.4
6.4
6.6
4.4
5.8
CFM
HIGH 220/215
220/215
220/215
310/300
210
225
LOW 195/190
195/190
195/190
240/230
195
200
HIGH 240/235
240/235
240/235
335/325
240
230
LOW 210/205
210/205
210/205
260/250
210
200
FAN ONLY*
65*
65*
65*
70*
65*
65*
COMPRESSOR & FAN*
65*
65*
65*
70*
65*
65*
Dehumidification
(pints/hr)
1.6
2.6
3.3
3.3
2.6
3.3
Net Weight
95
100
110
110
100
110
Shipping Weight
(approx. lbs.)
110
115
125
125
115
125
COOLING DATA (HEAT PUMP)
Cool, Wet Coil
Dry Coil