![Maytag Amana NTE07A A3A Series Service Instructions Manual Download Page 14](http://html1.mh-extra.com/html/maytag/amana-nte07a-a3a-series/amana-nte07a-a3a-series_service-instructions-manual_1747574014.webp)
14
SPECIFICATIONS
NOTES:
1. All 265V models must use Amana
®
brand’s subbase (PTSB4**E) or an Amana
®
brand hard wire kit (PTPWHWK4).
2. Minimum circuit ampacity ratings conform to the National Electric Code. However, local codes should apply.
Minimum voltage on 230/208 volt models is 197 volts; maximum is 253 volts.
3. Minimum voltage on 265 volt models is 238.5 volts; maximum is 291.5 volts.
4. Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265 volt models must be cartridge-style time delay fuses
(included and factory installed on Amana
®
brand all 265 volt chassis). See heater performance for total MCA.
5. Heating capacity and efficiency are based on unit operation without condensate pump. Unit automatically switches to electric heat at approximately 24°F outdoor ambient.
6. Total watts for 12,000 and 15,000 Btuh models. Subtract 70 watts for PT07/09
7. Please specify 2-digit heater kW size to complete model serial number.
8. Total amps for 12,000 and 15,000 Btuh models; subtract 0.2 amps for PT07/09
9. Refrigerant used in all systems is R-22.
10. All units meet or exceed ASHRAE 90.1 standards..
11. All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meeat UL 484 standards.
12. Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
PTH********[M/R/Z]
PTH
073D***[R/Z]
PTH
093D**AR
PTH
123C**AM
PTH
123D**AR
PTH
094D****
PTH
124C**AM
3.5/3.5
4.4/4.4
4.8/5.2
5.4/5.4
3.6
4.7
550/530
760/740
1,010/960
1,035/1,015
750
1,010
6,200/6,000
8,300/8,100
10,000/9,500
10,600/10,400
8,200
10,000
3.2/3.3
3.2
2.9
3.0
3.2
2.9
---
---
---
---
---
---
240/235
240/235
240/235
335/325
240
230
Outdoor
Ambient
ºF
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
Heating BTUH
Note 5
62
7,200/7,000
9,900/9,700
12,200/11,700
12,800/12,600
9,800
12,200
57
6,900/6,700
9,400/9,200
11,500/11,000
12,100/11,900
9,300
11,500
52
6,500/6,300
8,800/8,600
10,800/10,300
11,400/11,200
8,700
10,800
47
6,200/6,000
8,300/8,100
10,000/9,500
10,600/10,400
8,200
10,000
Rating
Point
(COP)*
ºF
3.2/3.3
3
2.9
3
3.2
2.9
42
5,900/5,700
7,800/7,600
9,300/8,800
9,900/9,700
7,700
9,300
37
5,600/5,400
7,300/7,100
8,600/8,100
9,200/9,000
7,200
8,600
32
5,300/5,100
6,800/6,600
7,800/7,300
8,400/8,200
6,700
7,800
27
5,000/4,800
6,300/6,100
7,100/6,600
7,700/7,500
6,200
7,100
24
4,800/4,600
6,000/5,800
6,700/6,200
7,300/7,100
5,700
6,700
Outdoor
Ambient
ºF
Watts
Watts
Watts
Watts
Watts
Watts
62 °F
585/570
820/800
1,110/1,065
1,135/1,110
810
1,110
57 °F
575/555
810/790
1,080/1,030
1,105/1,085
800
1,080
52 °F
560/545
785/765
1,050/1,000
1,075/1,055
775
1,050
47 °F
550/530
760/740
1,010/960
1,035/1,015
750
1,010
42 °F
540/525
740/720
975/925
1,000/980
730
975
37 °F
530/515
715/695
940/890
965/945
705
940
32 °F
515/500
700/680
890/840
915/895
690
890
27 °F
505/490
670/650
945/795
870/850
670
945
24 °F
500/485
650/630
900/770
845/825
650
900
BTUH
5
N Models
CFM (Dry)
*COP = Coefficiency of Performa nce; p er AHRI Test Procedures, units are rated for capacities and e fficien cies.
COP
5
M Models
Heating Capacity
Reverse Cycle
1
Amps
12
Watts
12
HEATING PERFORMANCE - REVERSE CYCLE
230V
208V
265V
230/208
2 .5/2.0
1
8 ,500
6,80 0
---
2,650/2,14 0
11.6 / 10.5
14.5
15
6 - 1 5 P
230/208
3 .5/2.9
1
12,000
9,90 0
---
3,650/3,04 0
15.9/14.5
19.9
20
6 - 2 0 P
230/208
5 .0/4.1
1*
17,100 14,000
---
5,150/4,24 0
22.4/20.4
28.1
30
6 -30 P
265
2.5
1
---
---
8,500
2,650
10.1
12.7
15
7 - 2 0 P
265
3.7
1
---
---
12,600
3,850
14.7
18.3
20
7 - 2 0 P
265
5.0
1*
---
---
17 ,100
5,150
19.6
24.5
25
7 - 3 0 P
* PTH/PTC09*B50*G/K have the same airflow as a PTC/P TH12*B***G (not available on 7,000 BTU/h models).
HEAT PERFORMANCE (ELECTRIC HEAT) ELECTRIC DATA
(ALL BTUH SIZES, ALL MODELS)
Nominal Heating
(BTUH)
Number
of
Stages
Electric Heater S ize
(kW)
Voltage
Total
Watts
Total
Amps
Minimum
Ampa city
1
Overcurrent
Protection
5
Power
Cord
1