27
MOUNTING SENSOR/DOOR MAGNET
INSTALLATION FOR DD01A KIT
A DT01* must be installed in the PTAC unit for the DD01* to be
operable.
Skip these steps if not installing.
1.
Remove motion sensor from mounting plate by pulling apart.
2.
Mount the back plate on the door trim directly above the
door using the enclosed screws. The bottom of the plate
must be within 3/8” of where the magnet will be mounted in
the door.
DO NOT SNAP MOTION SENSOR IN PLACE UNTIL
AFTER BINDING PROCESS.
DOOR
DOOR TRIM
(CENTER MAGNET WITH
01*)
DD
DD01*
3.
Install two (2) AAA batteries (batteries are included) into
the back of the thermostat. Terminals are marked “+” and
“-” for polarity.
DOOR MAGNET INSTALLATION
Mount the door magnet on the front of the door or the top of the
door, where it will be within 3/8” of the bottom center of the
motion sensor when the door is closed. There are (3) shims 3/
10” thick to be used as needed to bring magnet out flush with
the sensor back plate. Screws are included.
DO NOT SNAP MOTION SENSOR IN PLACE UNTIL AFTER
BINDING PROCESS.
DOOR
DOOR TRIM
(MAGNET MUST BE CENTERED WITH DD01A)
DD01A
FIGURE 1
CEILING
DD01A Mounting
3.
Install two (2) AAA batteries (included) into the back of
the thermostat. Terminals are marked “+” and “-” for po-
larity.
DOOR MAGNET INSTALLATION
Mount the door magnet holder on the front of the door where it
will be as close as possible to the bottom of the motion sensor
but no more then 1/8" from the bottom center of the motion
sensor (DD01*) when the door is closed.
Select the correct slot in the magnet holder (there are three
slots) to obtain 1/2" from back of sensor mounting plate to the
center of the magnet. (If you can easily slide a business card
between the magnet and the DD01* sensor, unit is properly
placed vertically.)
Screw in place with the 2 screws provided. Open and close the
door to make sure that the magnet holder and motion sensor
will not interfere with normal opening and closing of the door.
Sensor will not interfere with normal opening and closing of the
door.
PROPER INSTALLATION
MAGNET HOLDER TOP
SIDE
VIEW
D
OOR
T
R
IM
MAGNET
DOOR
1/8” max.
THE SPACE FROM
THE TOP OF
THE MAGNET HOLDER &
THE BOTTOM
OF THE
01*
CANNOT BE
MORE THAN 1/8”.
The ideal spacing allows a
business card to be
easily placed
between the D 01* sensor
and the magnet holder.
DD
D
MAGNET MUST
BE ½”
FROM THE
SENSOR
MOUNTING
PLATE
MAGNET HOLDER
MAY EXTEND
ABOVE THE DOOR
(OR THE DD01* MAY
EXTEND BELOW
THE DOOR FRAME)
TO ENSURE THE
MAGNET IS NO MORE
THAN 1/8” FROM THE
BOTTOM CENTER OF