TeraPac User Operation and Maintenance Guide
19
Figure 4-8
Note:
Any disks in the main MaxPac system are assigned numbers from 0 through 7. By
comparison, the disks in the TeraPac are always numbered starting at 8. The minimum number
of disks in a TeraPac are three (because this is the smallest number that can support RAID 5),
in which case these would be numbered 8, 9, and 10. The maximum number of drives is eight,
which will be numbered from 8 to 15.
17) Press the
<Space>
key to select the required array, which will turn from Gray (as shown in
Figure 4-8) to Green (as shown in Figure 4-9).
Figure 4-9
18) Press the
<F10>
key to configure the selected array, which will result in the
Logical Drives
Configured
dialog (Figure 4-10).