MaxStream 9 XTend- PKG- E Manual Download Page 5

9XTend

PKG

E™

 

Ethernet

 

RF

 

Modem

 

 

Product

 

Manual

 

v2.x4x

 

[2007.01.04]

©

 

2007

 

MaxStream,

 

Inc.,

 

Confidential

 

&

 

Proprietary

 ‐ 

All

 

Rights

 

Reserved

 

     

4

1.

 

9XTend

 

Ethernet

 

RF

 

Modem

The 9XTend RF Modem  affords OEMs and int egrat ors an easy- t o- use RF 
solut ion t hat  sust ains reliable delivery of dat a bet w een rem ot e devices. 

Out - of- box, t he m odem  is configured t o im m ediat ely  sust ain long range 
wireless links bet ween devices. Sim ply feed serial dat a int o one m odem  

t hen t he dat a w ill surface on t he ot her end of t he w ireless link. The 

m odem  t ransfers a st andard asynchronous serial dat a st ream  bet w een devices.

1 .1 . Ke y Fe a t u r e s

Lon g Ra n ge  D a t a  I n t e gr it y

1  W a t t  Pow e r  Out pu t

 ( variable 1m W -  1W)

Range ( @9,600 bps t hr oughput  dat a rat e) :

• I ndoor/ Urban:  

u p t o 3 0 0 0 ’

 ( 900 m )

• Out door  RF line- of- sight :  

 

up t o 1 4  m ile s

 ( 22 km )  w / dipole ant enna

• Out door  RF line- of- sight :

 

up t o 4 0  m ile s

 ( 64 km )  w / high- gain ant enna

Range ( @115,200 bps t hroughput  dat a rat e) :

• I ndoor/ Urban:  

u p t o 1 5 0 0 ’

 ( 450 m )

• Out door  RF line- of- sight :

 

up t o 7  m ile s

 ( 11 km )  w / dipole ant enna

• Out door  RF line- of- sight :

 

up t o 2 0  m ile s

 ( 32 km )  w / high- gain ant enna

Cont inuous RF dat a st ream  up t o 

1 1 5 ,2 0 0  bps

Receiver  Sensit ivit y:  

- 1 1 0  dBm

 ( @ 9600 baud) ,

 

1 0 0  dBm

 ( @ 115200 baud)

Adv a n ce d N e t w or k in g &  Se cu r it y

True Peer- t o- Peer ( no Mast er device required) ,

 

Point - t o- Point , Point - t o- Mult ipoint  & Mult idrop

Ret ries and Acknow ledgem ent s

FHSS ( Frequency Hopping Spread Spect rum )

10 hopping channels, each w it h over 65,000

 

unique net w ork addresses available

2 5 6 - bit  AES En cr y pt ion  

 

( AES algor it hm  is FI PS- 197 cer t ified)

Low  Pow e r

7 -  28 V Supply Volt age

Serial Port  and Cyclic

 

soft ware sleep m odes support ed

Ea sy- t o- Use

No configurat ion necessary for out - of box

 

RF com m unicat ions

Free X- CTU Soft ware

 

( Test ing and configurat ion soft war e)

RF Modem s easily configured using

 

st andard AT & binary com m ands

Transparent  Operat ion 

 

( Wireless links replace serial w ires)

API  Operat ion 

 

( Fram e- based com m unicat ions)

Port able 

 

( sm all form - fact or  easily designed int o 

 

a wide range of dat a syst em s)

Soft ware- select able I / O int erfacing rat es

Mult iple dat a form at s support ed

 

( parit y, st art  and st op bit s, et c.)

XI I ™ I nt erference I m m unit y

No Mast er/ Slave set up dependencies

Fr e e  &  Un lim it e d Te chn ica l Su ppor t

1 .1 .1 . W or ldw ide  Acce pt a n ce

FCC Appr ove d

 ( USA)  Refer t o Appendix A [ p56]  for FCC Requirem ent s.

 

Syst em s t hat  include XTend RF Modem s inherit  MaxSt ream ’s Cert ificat ions.

I SM

 ( I ndust r ial, Scient ific & Medical)  license- fr ee 902- 928 MHz fr equency band

Manufact ured under 

I SO 9 0 0 1 :2 0 0 0

 regist ered st andards

ESD  ( Ele ct r ost a t ic D isch a r ge )  im m u n it y

 -  ESD- har dened and I EC1000- 4- 2 ( Level 4)  t est ed

9XTend RF Modem s are opt im ized for use in t he 

US

Ca n a da

Au st r a lia  a n d I sr a e l

Summary of Contents for 9 XTend- PKG- E

Page 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Page 2: ...ww MaxStream net live chat support 9 XTend PKG E Ethernet RF Modem 9XTend Ethernet RF Modem System Setup RF Modem Operation RF Modem Configuration RF Communication Modes Appendices Pr odu ct M a n ua...

Page 3: ...ons and disclaimer Distributions in binary form include the above copyright notice this list of con ditions and disclaimer in the documentation and or other associated materials The copyright holder s...

Page 4: ...e 16 3 2 5 Command Mode 18 4 RF Modem Configuration 2 0 4 1 Program m ing Exam ples 2 0 4 1 1 Configuration Setup Options 20 4 1 2 AT Command Examples 21 4 1 3 Binary Command Example 21 4 2 Com m and...

Page 5: ...True Peer to Peer no Master device required Point to Point Point to Multipoint Multidrop Retries and Acknowledgements FHSS Frequency Hopping Spread Spectrum 10 hopping channels each with over 65 000 u...

Page 6: ...eceiver Sensitivity 110 dBm 100 dBm Power Requirements Supply Voltage 7 28V 7 28V Receive Current 270 mA 270 mA Serial Port Sleep Power Down 210 mA 210 mA Idle Currents 9V supply voltage 16 sec cyclic...

Page 7: ...wer connector 1 0 2 a Antenna Port Figure 1 02 Back View The antenna port is a 50 RF signal connector for connecting to an external antenna The connector type is RPSMA Reverse Polarity SMA female The...

Page 8: ...that can be identified by its DB 9 serial port and 6 switch DIP Switch XTend OEM RF Module OEM RF Module The OEM RF Module is mounted inside all XTend PKG RF Modems and may be integrated into OEM des...

Page 9: ...m Port Redirector MaxStream provides com port redirection software that creates a com port in the operating sys tem that will forward serial data to the I P address of the Ethernet connected RF modem...

Page 10: ...PC if prompted to do so 2 Launch the X CTU Software and select the PC Settings tab then select the Ethernet Com Ports sub tab Figure 2 03 After the Com Port Redirector is installed PC is re booted a...

Page 11: ...Com Port dialog box will appear the first time the Ethernet Com Ports sub tab is selected The following steps are written under the assumption the sub tab has already been selected at least one time 3...

Page 12: ...on 3 Configure the PKG R RS 232 RF Modem for RS 232 operation using the built in DIP Switch Dip Switch 1 should be ON up and the remaining switches should be OFF down 4 Attach RPSMA antennas to both R...

Page 13: ...Windows Select Start Run then type cmd without quotation marks in the text box of the Run dialog box Then select the OK button If using Linux or UNIX Run a command shell If using Mac OS X Run Applica...

Page 14: ...surrounded by the before and after guard times BT AT parameters If the DI buffer becomes full hardware or software flow control must be implemented in order to prevent overflow loss of data between t...

Page 15: ...ria is m et Figure 3 02 Transmit Mode Data Flow The character timeout trigger can be disabled by setting RO to zero In this case transmission will not begin until RB bytes have been received and are p...

Page 16: ...each time a new connection sequence begins The RF initializer contains channel information that notifies receiving modems of information such as the hopping pattern used by the transmitting modem The...

Page 17: ...to enter Sleep Mode the following condition must be met in addition to the modem hav ing a non zero SM parameter value When in Sleep Mode the modem will not transmit or receive data until the modem fi...

Page 18: ...the modem When the modem awakens to listen for data GPO1 is asserted and any data received on the DI Pin is transmitted The PWR pin is also de asserted low when the modem is in Cyclic Sleep Mode The m...

Page 19: ...eding example would change the modem s Destination Address to 0x1F To store the new value to non volatile long term memory the Write ATWR command must subsequently be sent before powering off the mode...

Page 20: ...the command will essentially be executed in the order it is received If the modem is continuously receiving data the radio will wait for a break in the received data before executing the command The C...

Page 21: ...on Connect the Ethernet RF Modem directly to the PC through the PC s Ethernet port as shown in the figure below Figure 4 02 Direct PC Connection Configuration Setup 1 Install both the X CTU Software a...

Page 22: ...store RF modem default parameter values OK CR Write to non volatile memory OK CR Exit Command Mode Method 2 Multiple commands on one line Send AT Com m and ATRE WR Enter ATCN Enter System Response OK...

Page 23: ...stination Address 0 0xFFFF Networking Security 2 0 E0 0x0A 10d Echo Off Command Mode Options E1 0x0B 11d Echo On Command Mode Options ER 0x0F 15d Receive Error Count 0 0xFFFF Diagnostics 2 0 FH 0x0D 1...

Page 24: ...acing 1 0 SB 0x37 55d Stop Bits 0 1 Serial Interfacing 1 0 SH 0x25 37d Serial Number High 0 0xFFFF read only Diagnostics 2 varies SL 0x26 38d Serial Number Low 0 0xFFFF read only Diagnostics 2 varies...

Page 25: ...esult of this command AP API Enable Com m and Serial Interfacing The AP command is used to enable the modem to operate using the frame based API operation AT Guard Tim e After Com m and Command Mode O...

Page 26: ...MaxStream s X CTU Software non standard interface data rates can only be set and read using the X CTU Terminal tab Non stan dard rates are not accessible through the Modem Configuration tab When the B...

Reviews: