Chapter 6 Operation Guide
(1) Description of buttons and indicator lights
"Setting" key: function cycle switch key, you can switch the indicator light display
in a circular way, switch the indicator light to the specified position, the group of
data is in the state of adjustable parameters, at this time, you can use the "+" "-"
keys to change the parameters .
"Run" key: Press this key after parameter change to confirm that the setting is
completed.
"Manual wire feed" key: Press to feed welding wire continuously and quickly,
release it to stop wire feeding.
"Manual retraction" key: Press to retract the welding wire continuously and
rapidly, release it to stop retracting the welding wire.
"Simulation Run" key: Press the button to continuously feed the wire according
to the set parameters, and release it to withdraw and stop according to the set
parameters, that is, to simulate the wire feeding withdrawal state during welding
under this parameter setting.
"Wire feeding speed" indicator light: It will light up after the setting switch is
selected. When this light is always on, the wire feeding speed can be adjusted
by the "+" and "-" keys.
"Wire feeding delay" indicator light: It will light up after the setting switch is
selected. When this light is always on, you can adjust the wire feeding delay by
pressing the "+" and "-" keys.
"Fixing distance" indicator light: It will light up after the setting switch is selected.
When this light is always on, you can adjust the distance of the supplementary
wire by pressing the "+" and "-" keys.
"Retraction distance" indicator light: When the setting switch is selected, it lights
up. When this indicator is always on, the retraction distance can be adjusted by
the "+" and "-" keys.