27
Chapter 3 Product Description
Alarm
information
Laser
The laser generator works abnormally, please
contact the after-sales service.
Communication
The communication between the laser and the
hand-held welding torch is abnormal, please check
whether the connection is abnormal, and contact
the after-sales service after confirming that it is
correct.
Galvo
If the galvanometer works abnormally, please
contact the after-sales service.
Wire feed
If the wire feeding is abnormal, please check
the power supply of the wire feeder, whether the
welding wire is short of wire or contact the after-
sales service. (Only support the abnormal alarm of
the built-in wire feeder)
Protective gas
If the pressure of the protective gas is abnormal,
please check whether the protective gas is turned
on and whether the gas cylinder is short of gas,
and contact the after-sales service after confirming
that it is correct.
Protective mirror
temperature
The temperature of the protective mirror is
abnormal, please check 1. Whether the protective
gas is turned on, whether the pressure is normal,
2. Whether the protective mirror is dirty; 3. After
confirming that it is correct, contact the after-sales
service.
(2) Advanced settings interface
This page is used to adjust other working parameters, including mode, enable,
and process, which are explained as follows.