Chapter 3 Product Description
Process
parameters
Laser
frequency
Sets the laser output frequency in discontinuous
mode.
duty cycle
Sets the laser output duty cycle in pulse/burst mode.
Shot duration Set the burst duration in burst mode.
Ramp up time Sets the laser ramp-up time in pulsed mode.
Blow delay
Sets the lead time for gassing before the laser is
fired.
Air off delay
Sets the delay time for shutting off the gas after the
laser is turned off.
Light off delay
Sets the delay time from stopping wire feeding to
turning off the laser for cutting the wire.
wire feed
speed
Set the wire feeding speed (this function only works
on the built-in wire feeding head)
(3) Process parameter interface
This page can preset 32 groups of fixed process parameters. To adapt to
different welding needs.