![background image](http://html1.mh-extra.com/html/maxon/mxt-25/mxt-25_maintenance-manual_1745182058.webp)
1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
58
PLATFORM WILL NOT TILT DOWN TO THE GROUND
1.
Lower the platform until shackles touch the
ground
(FIG. 58-1)
.
NOTE:
If the Liftgate is not damaged, the 1800 psi (lowering) pressure relief valve in
the pump may need to be adjusted as follows.
PLATFORM LOWERED WITH SHACKLES
TOUCHING THE GROUND
FIG. 58-1
SHACKLE
2.
Unbolt and remove pump cover
(FIG. 58-2)
.
UNBOLTING PUMP COVER
FIG. 58-2
CAP SCREW,
5/16”-18
(2 PLACES)
COVER
BRACKET
(2 PLACES)
FLAT WASHER,
5/16”
(2 PLACES)
NYLON NUT,
5/16”-18
(2 PLACES)
PUMP COVER
POWER UNIT