57
7.
Reconnect lock valve wiring harness
(FIG. 57-1)
.
RECONNECTING LOCK VALVE
WIRING HARNESS
FIG. 57-1
WIRING
HARNESS
COIL
CONNECTOR
BOLTING ON PUMP COVER
FIG. 57-2
8.
Bolt on the pump cover as
shown in
FIG. 57-2
. Torque the
5/16”-18 cover bolts from
10 to
14 lb-in
.
CAP SCREW,
5/16”-18
(2 PLACES)
COVER
BRACKET
(2 PLACES)
FLAT WASHER,
5/16”
(2 PLACES)
NYLON NUT,
5/16”-18
(2 PLACES)
PUMP COVER
POWER UNIT
(REF)