![Maxon GPC X1-LDF Installation Manual Download Page 66](http://html1.mh-extra.com/html/maxon/gpc-x1-ldf/gpc-x1-ldf_installation-manual_1745092066.webp)
Testing the liftgate
60
6.4 Explanation of diagnostic LED on the control unit
LED monitoring function
Cabin switch in
driver’s cabin or
key switch
LED off
LED on
LED
flashing
Platform closed (90°)
Off
X
Platform closed
On
X
Platform open (90° to 60°)
On
X
Platform open (60° to 0°)
On
X
Platform tilted down (0° to -10°)
On
X
Switch being actuated *
On
X
Description:
90° = Platform is closed
0° = Platform is open to the horizontal position
-10° = Tip of platform is tilted down
*If a control element on the handheld control (toggle switch, remote control
pushbutton, or foot switch) is actuated, the control LED flashes (see Fig. 91).
F
ig. 91
Legend:
X
Control unit LED for control function