Testing the liftgate
58
6 Testing the liftgate
6.1 Function test
Test: opening, lifting, lowering, tilting down, tilting up, closing
CAUTION
Platform at ground level
In the fully lowered position, the platform is easily overlooked and
may cause people to trip, resulting in injury.
If leaving the platform in this position for a longer period of time,
secure the area.
6.2 Testing the operating speed
6.2.1 Vertical speed
Test: vertical speed (lifting and lowering)
The vertical speed must not exceed (lifting and lowering) 15 cm/sec.
WARNING
Permissible vertical speed exceeded
Risk of injury when operating the liftgate.
Contact customer service.
6.2.2 Closing and opening speed (90° to 10°)
Test: angular velocity when opening and
closing (see Fig. 90)
The angular velocity when opening and closing
must not exceed
10°/sec.
WARNING
Permissible angular velocity exceeded
Risk of injury when operating the
liftgate.
Contact customer service.
6.2.3 Tilting speed (10° to -10°)
Test: angular velocity when tilting up and down (see Fig. 90)
.
The angular velocity when tilting up and down must not exceed
4°/sec.
WARNING
Permissible angular velocity exceeded
Risk of injury when operating the liftgate.
Contact customer service.
Fig. 90
Summary of Contents for GPC X1-LDF
Page 1: ...GPC X1 LDF liftgate Installation Manual for Mercedes Benz Sprinter...
Page 11: ...Introduction 5 2 1 4 Accessories kit Fig 4...
Page 13: ...Introduction 7 2 1 5 Installation adapter kit 22 911 216 Fig 5...
Page 71: ...Useful information 65 8 2 Assembly drawings of installation adapters...
Page 72: ...Useful information 66 8 3 Electrical circuit diagram...
Page 73: ...Useful information 67 8 4 Hydraulic circuit diagram...