background image

1

UL 325 2016 Standard-MAX Quick Install Rev 8

Quick Install Guide for

MAX 1500 / MAX 2200

Slide Gate Operators

www.max.us.com

4009963

Residential/Commercial

Brushless DC Slide Gate Operators

Made in USA

CONFORMS TO UL STD 325
UL CLASS - I, II, III, IV

CERTIFIED TO CAN/CSA STD
C22.2 NO. 247

SAFETY SENSORS REQUIRED

Version 8

Summary of Contents for MAX 1500

Page 1: ...l Guide for MAX 1500 MAX 2200 Slide Gate Operators www max us com 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO...

Page 2: ...el Gate 1500 lbs Uphill Gate 5 Max Opening Time Selectable speed control MAX 12 inch per second Cycles per Hour AC Power Continuous Battery Back Up Cycles Batteries fully charged MAX 1500 approximatel...

Page 3: ...apment protection CLOSING photocell and or sensing edge when not using Gate Link wireless transmitter In ground loop wires Conduit Guidelines and Suggestions 8 625 12 75 Conduit Area Input Power Condu...

Page 4: ...perator is NOT parallel to gate Chain is NOT parallel to gate DO NOT mount chain bracket too high on gate NO NO YES YES YES YES Drive Gear NOTE The chain should sag no more than one 1 inch per 10 feet...

Page 5: ...TIC OPEN CLO SE CONTR OLS BATTERY BACK UP MO DE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERRO R OPEN COM CLOSE Tamp er NO COM GN D Tamp er IN OFF OFF ON EXI T PARTIAL OPEN OBD PORT BLACK BOX MO TO R M...

Page 6: ...earth or a grounding rod Dual Gate Operators NOTE Secondary operator will automatically be set to the opposite opening direction as the primary gate operator W ARNIN G W ARNIN G connect chass is to g...

Page 7: ...ear reducer BEFORE cycling operator Breather Pin CAUTION REMOVE BEFORE OPERATION Limit Sensor Activator Limit Sensor Activator BLACK Limit Sensor Plug Plug PhotoCell Edge UL Entrap 1 2 Limit SW ON LIN...

Page 8: ...d le a rn m o d e b e e p in g s to p s In p u ts a re n o w M O N IT O R E D 2 3 2 3 O P E N S T O P C LO S E MO TO R MO TIO N M C 2 0 0 S lid e EDGE 1 N C CLOSING Direction ONLY GND C Reflector GND...

Page 9: ...ns when using wireless option If a self supporting post is being used then sensing edges need to be installed on EACH side of the post to protect against entrapment in the OPENING and CLOSING directio...

Page 10: ...ate An input command press remote button or exit loop is needed BEFORE the gate will reset and close again When the gate encounters an obstruction during the OPEN cycle it will reverse approximately 6...

Page 11: ...DR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE loops loop detectors 10 In Ground Loops Connections Safety Loops Wired in series Safety Loop Safety Loop Exit Loo...

Page 12: ...ELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE 12 VDC OR 24 VDC Radio Power 250 mA Max 4 Wire Radio 3 Wire Radio Card Reader Separate...

Page 13: ...back of the Gate Shut Off switch after servicing the operator to prevent the switch from accidentally being turned ON during normal operation Plug the wire back in and turn ON the switch only while se...

Page 14: ...GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLUG PARTIAL OPEN CLOSE TIMER MAX PHOTOCELL OFF SAFETY CENTER OFF ON EXIT GATE TA Tamp...

Page 15: ...ING GATE TAMPER If an existing alarm system Building alarm system is connected to the GATE TAMPER relay see previous page notify proper authorities BEFORE dropping the chain IMPROPER Dropping of Chain...

Page 16: ...RIX JOG JOG LEFT RIG HT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor OverLoad POWER MC 200 Motor Controller 1615 14 13 12 3 4 5 MAX LED ON Sensitivity Edge ERD MOTOR Power In ALARM BATTERY PAC...

Page 17: ..._CIO Communica on Established Fri 07 11 2014 10 57 38 ENTRAP PRI_MC Photo Cell Deac vated Fri 07 11 2014 10 57 34 ENTRAP PRI_MC Photo Cell Ac vated Fri 07 11 2014 10 57 21 INFO Radio Input Deac vated...

Page 18: ...rapment sensor wiring or missing jumper If BATTERY IN USE LED is ON and BATTERY BACK UP MODE switch Leave Open then battery may be too low and gate is kept OPEN If BATTERY IN USE LED is ON and BATTERY...

Page 19: ...n MAX 1500 MAX 2200 MAX F18 MAX 1500 MAX 2200 MAX F18 Insert ID PLUG module that is tethered to chassis into ID PLUG connector of Matrix 1 Check if AC POWER ON OFF SWITCH is ON Check 24 V wiring from...

Page 20: ...ly ignore the flashing Check if Gate Shut off switch is ON Turn it OFF If it is OFF cycle the switch ON then OFF Check if the chain is dropped If so gate is disabled for safety Re install chain and cy...

Page 21: ...ed or malfunctioning Sensor might need to be re learned Jumper between EDGE 2 and GND is missing or broken jumper is required if a sensor is not present Sensor on EDGE 2 input photocell or edge may ha...

Page 22: ...power ON OFF switch is ON If so check AC power BATTERY Plug not plugged in to BATTERY IN port on battery module see below Battery needs to be replaced if BATTERY TEST fails and REPLACE BATTERY LED is...

Page 23: ...FT RIG HT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor Ove rLoad POWER MC 200 Motor Controlle r 1615 14 13 12 3 4 5 MAX LE D ON Sen sitiv ity Ed ge ERD M O T O R P o w e r In A L A R M B A T T...

Page 24: ...jumper unused inputs Entrapment Protection Sensor Guidelines 1 CAUTION See installation instructions ATTENTION Voir la notice d installation Edge 2 Photo Cell MC 200 PWR 12V MUST be used ONLY power en...

Page 25: ...e and or Photo Cell can be wired to ANY of the 3 Inputs MC 200 PWR 12V MUST be used to power MONITORED sensors UNUSED inputs MUST remain JUMPERED or fault will occur GN D 1 2 3 GN D 1 2 3 Inputs MUST...

Page 26: ...i n g E d g e M o n i t o r e d P h o t o C e l l OR G N D J o g R T J o g L T Entrapment Pro tection Inputs M U S T j u m p e r u n u s e d i n p u t s Entrapment Pro tection Sensor Guidelines 1 C A...

Page 27: ...25 UL 325 2016 Standard MAX Quick Install Rev 8...

Page 28: ...n River Ave Fountain Valley Ca 92708 Tel 949 699 0220 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD...

Reviews: