2.4 OILING
Oiling is important in maintaining the initial performance of the unit for many years and
preventing problems. Oil the unit as outlined below.
2.4.1 Oil Types
The type of oil used has great influence on the performance and durability of the unit. When
selecting the oil, special attention should be paid to the temperature characteristics of oil. The
manufacturer has specified the type of oil to be used with this unit through analysis and R & D
on various types of oil. The specified type oil is provided in a 40cc (gr.) can or plastic container
(minimum supply unit) by the company.
<References>
The number of printers that can be oiled with the minimum supply unit (40gr):
·
G-36:Approx. 100 printers
·
O-3:Approx. 100 printers
2.4.2 Oiling Standard
·
Use G-18, G-2 and 0-3 oil for oiling this unit.
·
Before oiling during disassembly and reassembly, clean the unit well. Refer to Tables 2.4.3 "Oil-
ing point list" and Figs. 3.2 and 3~4 "Overall oiling diagram" for oiling points. (the numbers in
the oiling point list correspond to the numbers indicated in the overall oiling diagram.)
·
Oiling is classified into two ranks. Oil the points according to the ranks below.
Rank A: Oil once each year
Rank B: Oil after each 1,500,000 characters printed.
The oiling points should be oiled regardless of the ranks in the following situations:
·
Overhaul
·
Oil is wiped out during such operations as maintenance or inspection
·
The parts are disassembled or replaced
Model M190G Technical Manual
Board assembly terminal arrangement diagram