Overview and Operating Principle 1-3
· Printer Driving Voltage
Power supply voltage
11
5.0 +0.8/-0.5 VDC
(Ni-Cd battery, nominal voltage 4.8V)
· 5.0 ±0.5 VDC
(when stabilized power supply is used)
· NOTES:
· Can be applied to motor, print solenoid,
and fast paper feed trigger solenoid
· Use the same power supply.
· In all printing pattern used, even during
sending of current to print solenoids, the
voltage drop by the power supply volt-
age and from wiring resistance must be
0.8 V or less. Also, voltage loss in the
driver circuitry (driver saturation volt-
age) must be 0.4 V or less.
· Detector Input Voltage
5.0 +0.8/-1.7 VDC
· NOTES:
· Can be applied to reset detector, timing
detector.
· Can be used with the same printer driver
power supply.
· MCBF:1,500,000 lines
Reliability
12
· Printer life:2,250,000 lines
Environmental conditions for
13
operating
· Operating ambient temperature:
· a) When using the ERC-22
-10× to 50× (14× to 122×F)
(The assured temperature for printing is
0× to 50×C (32× to 122×F))
· b) When using the ERC-09
0× to 50×C (32× to 122×F)
· Operating ambient humidity:
10 to 90%RH (non-condensing)
· Printer side:
Connection
14
PCB fixed to the frame (with 2.5 mm
(0.098”) pitch copper pattern)
· Circuit side:
Flat cables or lead wires
· 91mm(W)
Overall dimensions
15
×
46.9mm(D)
×
15.8mm(H)
(3.58”(W)
×
1.85”(D)
×
0.62”(H))
· Approximately 100 g (approximately
Weight
16
0.23 lb) except ribbon cassette
· Manual feed knob
Factory options
17
Horizontal type
Outside diameter: 20 mm (0.79”)
Item
No.
Model M190G Technical Manual
Table 1.1 General Specifications
Model M190G