TROUBLESHOOTING
10 - 9
D-MAXE with OI-TS
www.maxcessintl.com
MI 2-292 1 C
Faulty behavior
The table below shows examples of faulty behavior, causes, and
how to remedy the fault. Often the cause is incorrect parameter
settings.
Faulty behavior
Reason
Remedy
Reference
The actuator is
moving too fast or
too slow.
The motor speed is
not set correctly.
Adjust the motor
speed
in section
The actuator does
not move in
"Automatic" mode.
The gain is set too
low.
Increase the gain
in section
The actuator is
mechanically locked.
Free the actuator and
clean the area.
The actuator vibrates
in the Automatic
operating mode..
The gain is set too
high.
Reduce the gain
in section
Cable connections
are loose.
Check all cable
connections to make
certain they are
securely fastened.
The actuator moves
in the wrong
direction in
"Automatic" mode.
The polarity is set
incorrectly.
Reverse the polarity
in section
Wrong job selected.
Select "Manual: mode
and check whether
the correct job is
selected.
The actuator does
not move in "Servo
Center" mode.
The gain for the
servo-center
transducer is set too
low.
Increase the gain
in section
The actuator is at the
stop because the
polarity is set
incorrectly.
Reverse the polarity
for the "Servo-center"
operation mode.
in section
The actuator vibrates
in the "Servo-center"
operating mode.
The gain for the
servo-center
transducer is set too
high.
Decrease the gain
in section