INSTALLATION
3 - 10
D-MAXE with OI-TS
www.maxcessintl.com
MI 2-292 1 C
M
ont
age.f
m
LEDs on the D-MAXE
Controller
Additional information about error messages that are displayed
may be found in Section
.
LED
Status
Indicates
E1
(X2/1)
Off
No Ethernet connection
Green or
Green
flashing
Ethernet connection detected
Yellow
Either a 10mbps connection or a
half-duplex connection is recognized
Ε2
(Ξ2/ 2)
Off
No Ethernet connection
Green or
Green
flashing
Ethernet connection detected
Yellow
Either a 10 mbps connection or a
half-duplex connection is recognized
NW
Off
No external device is connected to
connection X8
Green
External device recognized at
connection X8
(e.g. an operator interface OI-TS)
PR
Off
No power supply
Red
Power supply voltage too low, internal
voltage outside tolerance or internal
temperature too high
Green
Power supply and temperature OK
Yellow
No motor voltage