i
‐
SHWAK
V4
Inverter
air/water
chillers
and
heat
pumps
with
floor
‐
standing
and
remote
condensing
units
35
14
TECHNICAL
DATA
14.1
PERFORMANCE
DATA
PERFORMANCE
DATA
Units
Models
i
‐
SHWAK
V4
06
08
10
Cooling
Cooling
capacity
(1)
min/nom/max
kW
2,32
/
5,07
/
5,58*
2,95
/
6,12
/
6,73*
3,27
/
7,56
/
8,83*
Input
power
(1)
kW
1,74
2,11
2,43
EER
(1)
W/W
2,91
2,90
3,11
Cooling
capacity
(2)
min/nom/max
kW
3,65
/
6,87
/
7,56*
4,65
/
8,52
/
9,12*
5,4
/
10
/
11,35*
Input
power
(2)
kW
1,69
2,18
2,26
EER
(2)
W/W
4,06
3,91
4,43
SEER
(5)
W/W
3,82
3,84
4,91
Heating
Heating
capacity
(3)
min/nom/max
kW
2,78
/
6,57
/
7,23*
3,54
/
8,01
/
8,81*
4,69
/
10
/
10,8*
Input
power
(3)
kW
1,50
1,89
1,89
COP
(3)
W/W
4,38
4,24
4,24
Heating
capacity
(4)
min/nom/max
kW
2,28
/
6,15
/
6,76*
2,85
/
7,92
/
8,71*
3,9
/
9,51
/
10,3*
Input
power
(4)
kW
1,83
2,39
2,74
COP
(4)
W/W
3,36
3,31
3,47
SCOP
(6)
W/W
3,86
3,94
4,1
Energy
efficiency
Water
temperature
35°C/55°C
Class
A++
/
A+
A++
/
A+
A++
/
A+
PERFORMANCE
DATA
Units
Models
i
‐
SHWAK
V4
12
14
/
14T
16
/
16T
Cooling
Cooling
capacity
(1)
min/nom/max
kW
3,27
/
8,49
/
9,6*
5,3
/
11,46
/
12,05*
6,3
/
14,65
/
16*
Input
power
(1)
kW
2,74
3,70
4,52
E.E.R.
(1)
W/W
3,10
3,10
3,24
Cooling
capacity
(2)
min/nom/max
kW
5,4
/
11,9
/
13,1*
6,7
/
13,8
/
15,2*
8,7
/
15,69
/
16,3*
Input
power
(2)
kW
2,65
2,92
3,20
E.E.R.
(2)
W/W
4,49
4,72
4,90
SEER
(5)
W/W
4,93
4,99
5,06
Heating
Heating
capacity
(3)
min/nom/max
kW
4,69
/
12,1
/
12,7*
5,5
/
13,76
/
15,1*
7,1
/
15,21
/
15,9*
Input
power
(3)
kW
2,95
3,26
3,52
C.O.P.
(3)
W/W
4,1
4,22
4,32
Heating
capacity
(4)
min/nom/max
kW
3,9
/
11,3
/
12,1*
5,3
/
13,55
/
14,9*
6,50
/
15,17
/
15,80*
Input
power
(4)
kW
3,31
4,04
4,38
C.O.P.
(4)
W/W
3,41
3,35
3,46
SCOP
(6)
W/W
4,28
3,89
4,00
Energy
efficiency
Water
temperature
35°C/55°C
Class
A++
/
A+
A++
/
A+
A++
/
A++
Operating
conditions:
(1)
Cooling:
Outdoor
air
temperature
35°C;
inlet/outlet
temperature
12/7°C.
(2)
Cooling:
Outdoor
air
temperature
35°C;
inlet/outlet
temperature
23/18°C.
(3)
Heating:
Outdoor
air
temperature
7°C
DB
6°C
WB;
inlet/outlet
temperature
30/35°C.
(4)
Heating:
Outdoor
air
temperature
7°C
DB
6°C
WB.;
inlet/outlet
temperature
40/45°C.
(5)
Cooling:
water
temperature
inlet/outlet
12/7°C.
(6)
Heating:
normal
climatic
condition;
T
biv
=
‐
7°C;
eater
temperature
inlet/outlet
30/35°C.
(*)
Maximum
Hz
function
activation.
N.B.
The
performance
data
are
indicative
and
could
be
subject
to
change.
In
addition,
the
performances
declared
in
apex
(1),
(2),
(3)
and
(4)
refer
to
the
instantaneous
power
according
to
EN
14511.
The
declared
data
stated
in
the
apex
(6)
is
determined
according
to
the
UNI
EN
14825.
WARNING:
The
minimum
temperature
allowed
for
storing
the
units
is
5°C.