40
15.1
MAXIMUM
POWER
CONSUMPTION
/
MAXIMUM
INPUT
CURRENT
OF
THE
INDOOR
UNITS
10
‐
12
Model
Electric
heater
MAR1
10
‐
12
MAR3
10
‐
12
MARS1
10
‐
12
MARS3
10
‐
12
NOT
PRESENT
0,14
kW
1,16
A
0,14
kW
1,16
A
0,22
kW
1,76
A
0,22
kW
1,76
A
DHW
electric
heater
of
1,2
kW
1,40
kW
6,64
A
1,47
kW
7,14
A
DHW
electric
heater
of
2
kW
2,14
kW
9,85
A
2,14
kW
4,05
A
2,22
kW
1,76
A
2,22
kW
4,65
A
DHW
electric
heater
of
3
kW
3,14
kW
14,20
A
3,14
kW
5,49
A
3,22
kW
14,80
A
3,22
kW
6,09
A
DHW
electric
heater
of
4,5
kW
4,64
kW
20,72
A
4,64
kW
7,66
A
4,72
kW
21,32
A
4,72
kW
8,26
A
DHW
electric
heater
of
3+3
kW
6,14
kW
9,83
A
DHW
electric
heater
of
4,5+3
kW
7,64
kW
12,00
A
DHW
electric
heater
of
4,5+4,5
kW
9,14
kW
14,16
A
Power
supply
230V/1/50Hz
400V/3P+N+T/50Hz
230V/1/50Hz
400V/3P+N+T/50Hz
Model
Electric
heater
MARP1
10
‐
12
MARP3
10
‐
12
MARPS1
10
‐
12
MARPS3
10
‐
12
NOT
PRESENT
0,14
kW
1,16
A
0,14
kW
1,16
A
0,22
kW
1,76
A
0,22
kW
1,76
A
DHW
electric
heater
of
1,2
kW
1,4
kW
6,64
A
1,48
kW
7,24
A
Plant
side
electric
heater
of
1,2
kW
1,4
kW
6,64
A
1,48
kW
7,24
A
DHW
E
‐
heater
of
1,2
kW
and
plant
E
‐
heater
of
1,2
kW
2,66
kW
12,11
A
2,74
kW
12,71
A
DHW
electric
heater
of
2
kW
2,14
kW
9,85
A
2,14
kW
4,05
A
2,22
kW
10,45
A
2,22
kW
4,65
A
DHW
electric
heater
of
3
kW
3,14
kW
14,20
A
3,14
kW
5,49
A
3,22
kW
14,80
A
3,22
kW
6,09
A
DHW
electric
heater
of
4,5
kW
4,64
kW
20,72
A
4,64
kW
7,66
A
4,72
kW
21,32
A
4,72
kW
8,26
A
Plant
side
electric
heater
of
2
kW
2,14
kW
9,85
A
2,14
kW
4,05
A
2,22
kW
10,45
A
2,22
kW
4,65
A
Plant
side
electric
heater
of
3
kW
3,14
kW
14,20
A
3,14
kW
5,49
A
3,22
kW
14,80
A
3,22
kW
6,09
A
Plant
side
electric
heater
of
4,5
kW
4,64
kW
20,72
A
4,64
kW
7,66
A
4,72
kW
21,32
A
4,72
kW
8,26
A
DHW
E
‐
heater
of
2
kW
and
Plant
E
‐
heater
of
2
kW
4,14
kW
18,55
A
4,14
kW
6,94
A
4,22
kW
19,15
A
4,22
kW
7,54
A
DHW
E
‐
heater
of
2
kW
and
plant
E
‐
heater
of
3
kW
5,14
kW
8,38
A
5,22
kW
8,98
A
DHW
E
‐
heater
of
2
kW
and
plant
E
‐
heater
of
4,5
kW
6,64
kW
10,55
A
6,72
kW
11,15
A
DHW
E
‐
heater
of
3
kW
and
plant
E
‐
heater
of
2
kW
5,14
kW
8,38
A
5,22
kW
8,98
A
DHW
E
‐
heater
of
3
kW
and
plant
E
‐
heater
of
3
kW
6,14
kW
9,83
A
6,22
kW
10,43
A
DHW
E
‐
heater
of
3
kW
and
plant
E
‐
heater
of
4,5
kW
7,64
kW
12,00
A
7,72
kW
12,60
A
DHW
E
‐
heater
of
3+3
kW
6,14
kW
9,83
A
DHW
E
‐
heater
of
3+3
kW
and
Plant
E
‐
heater
of
2
kW
8,14
kW
12,72
A
DHW
E
‐
heater
of
3+3
kW
and
plant
E
‐
heater
of
3
kW
9,14
kW
14,16
A
DHW
E
‐
heater
of
4,5
kW
and
plant
E
‐
heater
of
2
kW
6,64
kW
10,55
A
6,72
kW
11,15
A
DHW
E
‐
heater
of
4,5
kW
and
plant
E
‐
heater
of
3
kW
7,64
kW
12,00
A
7,72
kW
12,60
A
DHW
E
‐
heater
of
4,5
kW
and
plant
E
‐
heater
of
4,5
kW
9,14
kW
14,16
A
9,22
kW
14,76
A
DHW
E
‐
heater
of
4,5+3
kW
7,64
kW
12,00
A
DHW
E
‐
heater
of
4,5+4,5
kW
9,14
kW
14,16
A
Power
supply
230V/1/50Hz
400V/3P+N+T/50Hz
230V/1/50Hz
400V/3P+N+T/50Hz
The
electrical
data
of
the
outdoor
and
indoor
units
are
set
to
scale
the
size
of
the
circuit
breakers
and
power
supply
cables.
You
have
to
add
the
input
power
of
the
outdoor
unit
(see
Paragraph
14.2)
and
indoor
unit
taking
into
account
the
power
of
the
installed
electric
heater
kit.