SHWAK
V4
Inverter
air/water
chillers
and
heat
pumps
with
floor
‐
standing
and
remote
condensing
units
15
Herein
below
is
represented
the
correspondence
between
the
RE
variants
and
the
name
of
its
electric
heaters,
depending
on
the
electric
power
supply
of
the
unit.
When
ordering
you
must
specify
the
electric
heaters
of
both
DHW
the
technical
puffer
tank
and
plant
side
puffer
tank.
Filed
Variant
Description
Name
1
‐
phase
3
‐
phase
DHW
Plant
DHW
Plant
RE
00
Without
electric
heater
/
/
/
/
11
DHW
electric
heater
of
2
kW
RE2.0M2
/
RE2.0T
/
12
DHW
electric
heater
of
3
kW
RE3.0M2
/
RE3.0T
/
13
DHW
electric
heater
of
4,5
kW
RE4.0M2
/
RE4.0T
/
14
Plant
side
electric
heater
of
2
kW
/
RE2.0M2
/
RE2.0T
15
Plant
side
electric
heater
of
3
kW
/
RE3.0M2
/
RE3.0T
16
Plant
side
electric
heater
of
4,5
kW
/
RE4.0M2
/
RE4.0T
17
DHW
heater
of
2
kW
+plant
side
heater
of
2
kW
RE2.0M2
RE2.0M2
RE2.0T
RE2.0T
18
DHW
heater
of
2
kW
+
plant
side
heater
of
3
kW
/
/
RE2.0T
RE3.0T
19
DHW
heater
of
2
kW
+
plant
side
heater
of
4,5
kW
/
/
RE2.0T
RE4.0T
20
DHW
heater
of
3
kW
+
plant
side
heater
of
2
kW
/
/
RE3.0T
RE2.0T
21
DHW
heater
of
3
kW+
plant
side
heater
of
3
kW
/
/
RE3.0T
RE3.0T
22
DHW
heater
of
3
kW
+
plant
side
heater
of
4,5
kW
/
/
RE3.0T
RE4.0T
23
DHW
heaters
3
+3
kW
/
/
RE3+3T
/
24
DHW
heaters
3+3
kW
+
plant
side
heater
2
kW
/
/
RE3+3T
RE2.0T
25
DHW
heaters
3+3
kW
+
plant
side
heater
3
kW
/
/
RE3+3T
RE3.0T
26
DHW
heaters
4,5
kW
+
plant
side
heater
2
kW
/
/
RE4.0T
RE2.0T
27
DHW
heater
4,5
kW
+plant
side
heater
3
kW
/
/
RE4.0T
RE3.0T
28
DHW
heater
4,5
kW
+
plant
side
heater
4,5
kW
/
/
RE4.0T
RE4.0T
29
DHW
heaters
4,5+3
kW
/
/
RE4,5+3T
/
30
DHW
heaters
4,5
+
4,5kW
/
/
RE4,5+4,5T
/
32
DHW
electric
heaters
of
1,2
kW
/
/
33
Plant
electric
heaters
of
1,2
kW
/
/
34
DHW
electric
heaters
of
1,2
kW
+
Plant
electric
heaters
of
1,2
kW
/
/
7.1 OPTIONAL
ACCESSORIES
NO
FACTORY
FITTED
ACCESSORIES
(OPTIONAL)
AG
Rubber
shock
absorbers
to
be
inserted
at
the
basement
of
the
outdoor
unit
to
dampen
possible
vibrations.
KAS
Antifreeze
kit.
It
uses
a
self
‐
heating
cable
wrapped
at
the
basement
of
the
outdoor
unit
near
the
condensing
coil.
IMPORTANT
ONLY
THE
NO
FACTORY
‐
FITTED
OPTIONAL
ACCESSORIES
CAN
BE
REQUIRED
AFTER
THE
ORDER
OF
THE
UNIT,
WHILE
THE
FACTORY
‐
FITTED
OPTIONAL
ACCESSORIES
CANNOT
BE
REQUIRED
AFTER
ORDERING
OF
THE
UNIT.
WARNING:
The
optional
accessories
are
subject
to
revisions.
They
may
be
changed
without
the
need
to
update
the
previous
manuals
and
without
giving
prior
notice.
If
you
are
interested
in
buying
these
accessories
after
you
have
purchased
the
unit,
please
contact
our
offices
for
the
availability.