background image

19

4. PROTECTIVE DEVICE

If internal heat builds up during operation due to 
clogging of the airflow orifice, if the machine is 
used in a highly heated environment or if an ab-
normality occurs inside the machine, the thermal 
protector for preventing burnout may be activat-
ed to stop the motor operation. The buzzer will 
sound in this case. In such a case:

1. Turn the power switch off and disconnect 

the power plug from the outlet.

For buzzer sounding patterns, see 
page 21.

2. Connect the power plug to the outlet and 

turn the power switch on to resume the 
operation.

If the motor has sufficiently cooled down, 
the resumed operation may active the pro-
tective device soon after. In other cases, 
the operation may not resumed when you 
turned the power switch on. In such a 
case, wait for about 30 minutes for the mo-
tor to cool down before restarting the ma-
chine.

3. If the protective device was activated 

when there were no apparent problems 
existing in the operating environment, 
stop using the compressor and send it to 
your dealer or authorized service facility 
for checkups or repairs.

OFF

  AC

110V

  AC

110V

WARNING

AKHL1230E_UK.fm  19 ページ  2008年12月10日 水曜日 午後6時4分

Summary of Contents for powerlite AKHL1230E

Page 1: ...UK HIGH PRESSURE COMPRESSOR OPERATING and MAINTENANCE MANUAL BEFORE USING THIS TOOL STUDY THIS MANUAL TO ENSURE SAFETY WARNING AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFEREN...

Page 2: ...ES 21 7 AUTOMATIC ADJUSTMENT OF OPERATING POWER INVERTER CONTROL 22 8 IN ORDER TO MAINTAIN PERFORMANCE 22 READ THE INSTRUCTION HANDBOOK Before positioning operating or adjusting the compressor read th...

Page 3: ...PRES SURE AIR HIGH PRESSURE COMPRESSOR IS DESIGNED ONLY FOR MAX POWERLITE NAILERS AND POWERLITE HOSE UNSPECI FIED USAGE WILL CAUSE SERIOUS ACCI DENTS 1 NEVER TOUCH MOVING PARTS Never place your hands...

Page 4: ...rp edges 12 MAINTAIN COMPRESSOR WITH CARE Follow instructions for lubricating Inspect cords periodically and if damaged have re paired by authorized service facility 13 USE A SAFE EXTENSION CORD In or...

Page 5: ...p frequently 19 OPERATE COMPRESSOR AT THE RAT ED VOLTAGE Operate the compressor at voltages speci fied on their nameplates If using the com pressor at a higher voltage than the rated voltage it will r...

Page 6: ...tilt compressor to emp ty accumulated water 28 DO NOT STOP COMPRESSOR BY PULL ING OUT THE PLUG Use the ON OFF switch 29 WHENEVER USING THE HIGH PRESSURE SIDE OF THE MAX POWERLITE COMPRES SOR THE GENUI...

Page 7: ...er with the air and this could result in an explosion 35 NEVER USE THE TOOL IN AN EXPLO SIVE ATMOSPHERE Sparks from the tool may ignite atmospheric gases dust or other combustible materials 36 BE SURE...

Page 8: ...asured free field at a distance of 1m ISO2151 Product No AKHL1230E UK Power supply 110V 10 50Hz 1 1 Rated current 13A Motor power 2HP Protective earthing Class I Protective structure IP20 Working temp...

Page 9: ...protection NOTE The information contained in this Instruc tion Manual is designed to assist you in the safe operation and maintenance of the compressor Some illustrations in this Instruction Manual ma...

Page 10: ...TY WOODEN CHIPS ETC PLACE 6 INSTALL THE MACHINE IN THE APPRO PRIATE DIRECTION Install it appropriately 7 NEVER INSTALL THE MACHINE IN THE RAIN OR IN A PLACE SPLASHED WITH WATER OR EXPOSED TO HIGH TEMP...

Page 11: ...CE AN OBJECT ON THE TOP OF THE MACHINE Neglect of this could cause a trouble or break it Do not use the compressor in any place where the temperature is 0 C or less or the ambient temperature exceeds...

Page 12: ...indicating the set reduction valve pressure 2 gauges General purpose air chuck for regular pressure tools Power plug Power cord Drain cock Pressure reduction valve adjustment handle L Yellow cap Cont...

Page 13: ...mum on the H side and 8 3 bar maximum on the L side High pressure air chuck for MAX tools It connects the MAX air hose for the tools General purpose air chuck for reg ular pressure tools It connects t...

Page 14: ...tripping of the circuit breaker is anticipated during continuous operation Press the Power saving switch in Silent mode to turn on this mode A buzzer sounds with a beep and the LED lights up when the...

Page 15: ...ssure gauge 1 After turning off the machine power switch connect the earthing plug of the power plug to ground and then connect the power plug to the outlet When using an extension cord or drum cord m...

Page 16: ...ds the operating hours 7 Wait for 5 minutes after the operation is stopped to confirm that there are no ab normal noises or air leakages and that the compressor does not restart 8 Discharge the compre...

Page 17: ...level When ad justing the pressure turn the pressure reduction valve s adjustment handle counterclockwise to set the pressure at a level lower than the appropriate value by 2 bars once Then proceed t...

Page 18: ...ng the air hose to the air outlet air chuck 4 Connect the high pressure hose to the high pressure air hose for MAX PowerLite tools to the high pressure air chuck on the H side of the pressure reductio...

Page 19: ...ns see page 21 2 Connect the power plug to the outlet and turn the power switch on to resume the operation If the motor has sufficiently cooled down the resumed operation may active the pro tective de...

Page 20: ...s with the power supply or wiring See PROTEC TIVE DEVICE on page 19 Turning on the power switch does not start up the machine Motor vibration is generated 2 Abnormal sounds are generated during operat...

Page 21: ...p automatically LED remains lighting up with intermittent long beep sounds Pi Pi Pi until power switch is turned off Buzzer sounds Symptom Actions taken A one time short beep sound Pi At powering on W...

Page 22: ...ply with a power tool When capacity of the main power is 110 V or less or when it is jointly used with another power tool a radical voltage drop results in ducing startup failure The circuit breaker o...

Page 23: ...g it against solid objects or hitting it can cause deformation cracks or damage to the machine The User is advised not to invite an accident by dropping bumping or hitting the machine 5 Inspect the ma...

Page 24: ...e without advance notice due to our continuous efforts to improve the quality of our products 4007917 081210 00 00 PRINTED IN JAPAN OSTSTRASSE 22 40211 D SSELDORF GERMANY TEL 49 211 9365300 FAX 49 211...