BLADE
9-2
TI215G0010
Maintenance
pERIODIC MAINTENANCE TAbLE
CHECK
FREqUENCy - EvERy
The event that occurs first
OpERATING HOURS
EvERy
50
200
500
1000
5000
Tighten nuts and screws fixing the
cables in the command and control
electrical board and in the terminal
board of electrical motors
after the first 50 hours and
then every 6 months
Clean the oil return valves
within the first 300 hours
of operation and then
every 3 months
Check the oil level
week
Check and Clean the solenoid valve
filter of condensate drain (with
optional kit)
week
Clean the suction filter
month
Clean the oil radiator
month
Clean the air radiator
month
Clean the intake pre-filter
month
Rotoroil F2 oil change*
2 years
* For other lubricant refer to Section 10
!
wARNING !!!
In dusty environments and/or at high temperatures maintenance operations should be carried out more
frequently.
The manufacturing date is quoted on rubber hoses.
Their operating life is 3 years, after which they should be replaced.
!
wARNING !!!
For compressors equipped with INvERTER, before performing any maintenance job, wait at least 5
minutes after you have disconnected the electricity supply.
!
wARNING !!!
Scheduled maintenance agreements are available, to help the user keeping the machines at best operating
and efficiency conditions. Please apply to Ing. ENEA MATTEI S.p.A. for further details.