TI008G0001
7.03
Maintenance
Check of oil level
(Photo 1)
With compressor not operating and with-
out pressure inside the chamber the oil
level should be included between the MIN
and MAX levels shown on the specific in-
dicating sticker (fig. 1).
When the compressor is running and on load, the
oil level should be over the visual indicator half
(fig. 1).
Cleaning/replacing the air intake filter
(Photo 2)
Release the fixing hooks to remove the filter cover.
Firstly take out the outer element, then the inner
element by using the specific knob. Clean with
compressed air, directing the air jet from the inside
to the outside. Reassemble in the reverse order.
To clean the air end, remove
the soundproof panel and
proceed as above, by blow-
ing the radiator by means of
a compressed air flow.
Therefore the dust deposits mainly on the bottom.
To clean the oil radiator, remove the fan guard panel
(photo 4) and blow the radiator with a compressed
air flow.
Cleaning the oil/air radiator
(Photo 3)
Considering the air flow used to wash the compres-
sor, the radiator is crossed by an air flow directed
from downwards to upwards.
924
4
223
3
222
2
618
101
1