9.02
Troubleshooting
PROBLEM
C. Oil
Excessive oil consumption; the
oil the level lowers too quickly;
clogged; oil is detected inside the
system.
D. Temperature
The compressor stops due to its own
over-heating.
The compressor stops due to the
over-heating of the motor.
SOLUTION
Replace filters and verify the causes of
the clogging.
(see Section 7)
Replace the filters and verify the causes
of clogging.
(see section 7)
Verify the setting and re-set to the value
foreseen for the machine.
(see Section 7)
Verify the environmental conditions and
the condition of the filtering panel.
(see Sections 3 and 7)
CAUSE
The oil return valve filters are clogged.
The radiator or the cooling air filter are
Dirty the ambient temperature is too
hight for compressor operation.
Excessive working pressure.
The motor cooling is not sufficient;
There is not enough air or it is too hot.
TI008G0001