52
Matrix SETU ATA211 System Manual
For calls made from the FXS port, select the destination trunk for the option
If dialed number does
not match with either of the programmed number in the Dialed Number Table & call is made
from FXS, route the call through.
Default: SIP Trunk 1.
For calls made from the FXO port, select the destination trunk for the option
If dialed number does
not match with either of the programmed number in the Dialed Number Table & call is made
from FXO, route the call through.
Default: SIP Trunk 1.
•
Click
Submit
and close the window.
To know more, see
“Dialed Number Table”.
2.
If you want to
Authenticate Outgoing Calls
from the FXS port only after users have authenticated
themselves with their PIN, enable the
PIN Authentication
check box. Default: Disabled.
If you enable PIN Authentication, you must configure the PIN Authentication Table. To do this,
•
Click the arrow icon.
•
The
PIN Authentication Table
page opens in a new window.
•
Enter the PIN to be authenticated against each Index in the Table.
PIN number can be of a maximum of 4 digits. The characters allowed are: 0-9,*, #.