background image

Operating manual  

pneuMATO-fill 

MATO 

GmbH & Co. KG

 / Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120 

 

10

Intended use / guarantee 

The pressurised air filling device pneuMATO fill is suitable for filling of central lubrication 
systems with commercial lubricants up to NLGI grade 2. The pump works fully automatically. 

 

Grease and pastes, which are based on silicone oil and thickened with PTFE, are 

not

 allowed to 

 

be used with this device. Direct enquires to our technical department. 
 
If used as intended and in accordance with the instructions, we are liable under the statutory 
warranty. The invoice from your dealer with the date of purchase must be enclosed with 
warranty claims. 

Assembly and delivery  

The structure, including the individual components, is depicted on page 3. The pumps work fully 
automatically. Grease is produced once air pressure has accumulated and the trigger of the 
grease gun is pressed. If the trigger is released, the pump automatically stops grease 
production. It is equipped with the centering cover pictured below.  

 

The exact scope of delivery is shown in the order confirmation. 

 
 
 

Average centering cover 

 

 

Size of cover  Diameter of outside of cover 

10 - 15 

from 215 mm to 285 mm 

20 - 25 

from 270 mm to 340 mm 

50 

from 340 mm to 410 mm 

 

 

 

 

Set up and operation (stationary) 

Open grease container and press grease sequence piston firmly on the grease.  

Set centering cover on the grease container.  

Loosen all 3 wing screws and push the centering slide inside (towards the middle).  

Push the retaining claws outside with the bolts until the stopper.  

Now put the centering cover on the grease container so that the retaining claws are located 
outside of the centering slide within the grease container. 

Push the centering slide outside with the wing screw until the stopper. (Cover will centre itself 
independently on the grease container) 

Hold the wing screw pressed towards outside and push the retaining claws inside with the bolts 
until the stopper.  Tighten wing screw firmly.  

Secure the remaining 2 wing screws and bolts as described before.  

 

Warning!! 

 Check whether the centering cover is sitting securely on the grease container.  

The pump can now be pushed through the clamp and secured by clamping screws. 

Insert ZSA-hydraulic clutch on the plug of the central lubrication. 

The pneuMATO fill is now operational.  

When the system is not in use turn off the air supply to the pump. 

 

Observe safety instructions. 

 
 
 
 

 

Centering slide with 
wing screw 

Retaining claw with bolts 

 

grease 
container 

Ø for grease 

Securing nut 
 

Summary of Contents for pneuMATO-fill

Page 1: ...etriebsanleitung Operating Instructions Mode d emploi Instrucciones de empleo Instrucciones de empleo MATO GmbH Co KG Benzstr 16 24 63165 M hlheim a Main Tel 49 0 6108 906 0 Fax 49 0 6108 906 120 Erst...

Page 2: ...Operating manual Mode d emploi Instrucciones de uso pneuMATO fill MATO GmbH Co KG Benzstr 16 24 63165 M hlheim a Main Tel 49 0 6108 906 0 Fax 49 0 6108 906 120 2 Deutsch 3 7 English 8 12 Fran ais 13...

Page 3: ...9 0 6108 906 120 3 Die Baugruppe besteht aus folgenden Hauptkomponenten 1 Absperrhahn 2 ZSA Hydraulikkupplung 3 Gummi Panzerschlauch 4 Luftanschluss mit Filter 5 Fettauslass 6 Zentrierdeckel mit Zentr...

Page 4: ...Benutzung sind Schutz Handschuhe aus Leder sowie eine Schutzbrille zu tragen Hochdruckschlauch nicht scharf abknicken Hinweise Reparatur Wartung F r den Betrieb von pneumatischen Pumpen wird unbedingt...

Page 5: ...eckel Deckelgr e Beh lterau endurchmesser 10 15 von 215 mm bis 285 mm 20 25 von 270 mm bis 340 mm 50 von 340 mm bis 410 mm 4 Inbetriebnahme und Bedienung station r Fettbeh lter ffnen und Fettfolgekolb...

Page 6: ...r Pumpe beim Ansaugvorgang leicht ge ffnet max Umdrehung wird Die im Pumpensystem befindliche Luft kann dann leicht entweichen Sobald das Fett angesaugt ist Pumpe abstellen und Schlauchverbindung fest...

Page 7: ...ge pro Doppelhub Fett NLGI Klasse 000 Fett NLGI Klasse 2 Luftdruck min max Lautst rke 1 3 24 bar 20 ccm 3500 ccm min 1750 ccm min 3 8 bar ca 85 dB A Gewinde Luftanschluss Fettauslass Saugrohr Durchmes...

Page 8: ...he assembly unit consists of the following main components 1 Stopcock 2 ZSA hydraulic clutch 3 Reinforced rubber hose 4 Air connection with filter 5 Grease outlet 6 Centering cover with centering slid...

Page 9: ...of leather and goggles must be worn during use Do not bend high pressure hose sharply Instructions for Repair Maintenance For the operation of pneumatic pumps the fitting of a pressurised air maintena...

Page 10: ...iameter of outside of cover 10 15 from 215 mm to 285 mm 20 25 from 270 mm to 340 mm 50 from 340 mm to 410 mm 4 Set up and operation stationary Open grease container and press grease sequence piston fi...

Page 11: ...mp system if the hose connection is opened slightly at the pump during the intake process max revolution The air trapped in the pump system can then escape easily As soon as the grease is sucked in sw...

Page 12: ...in max Volume level 1 3 24 bar 20 ccm 3500 ccm min 1750 ccm min 3 8 bar ca 85 dB A Thread Air connection Grease outlet Suction tube diameter Rp R 40 mm Suction tube length 525 mm 790 mm 940 mm 1490 mm...

Page 13: ...us groupe sont 1 Robinet de fermeture 2 Accouplement hydraulique ZSA 3 Tuyau en caoutchouc gaine m tallique flexible 4 Branchement air filtre 5 Sortie de la graisse 6 Couvercle de centrage avec pousso...

Page 14: ...est obligatoire pour la manipulation Ne pas replier le tuyau de haute pression Conseils pour la r paration la maintenance Pour la mise en service de pompes pneumatiques il est express ment recommand...

Page 15: ...i dessous Le contenu de la livraison se d gage de la confirmation de la commande Coupe couvercle de centrage Taille du couvercle Diam tre externe du r servoir 10 15 de 215 mm 285 mm 20 25 de 270 mm 34...

Page 16: ...accord de tuyau sur la pompe pendant l aspiration max tour L air qui se trouve dans le syst me de la pompe peut s chapper plus facilement D s que la graisse est aspir e arr tez la pompe et serrez fond...

Page 17: ...3500 cm3 min 1750 cm3 min 3 8 bar environ 85 db A Pas de vis Branchement de l air Sortie de la graisse Diam tre du tuyau d aspiration Rp R 40 mm Longueur du tuyau d aspiration 525 mm 790 mm 940 mm 1...

Page 18: ...o de los siguientes componentes principales 1 Llave de paso 2 Embrague hidr ulico ZSA 3 Manguera reforzada de goma 4 Conexi n aire con filtro 5 Descarga de grasa 6 Cubierta central con armaz n central...

Page 19: ...as Durante su uso debe llevar guantes protectores de cuero y gafas protectoras No cortar de manera afilada la manguera de alta presi n Advertencias a tener en cuenta en reparaciones mantenimiento Para...

Page 20: ...La capacidad de entrega aparece en la confirmaci n del pedido Corte de cubierta central 4 Puesta en marcha y utilizaci n fija Abrir dep sito de grasa y apretar firmemente la grasa con el pist n seguid...

Page 21: ...ante el proceso de succi n m x vuelta A continuaci n se puede dejar escapar lentamente el aire que se encuentra en el sistema de bombeado Una vez que la grasa se haya absorbido apagar la bomba y fijar...

Page 22: ...ccm 3500 ccm min 1750 ccm min 3 8 bares aprox 85 dB A Rosca Conexi n aire Descarga de grasa Di metro del colector de admisi n Rp R 40 mm Longitud del colector de admisi n 525 mm 790 mm 940 mm 1490 mm...

Page 23: ...umple con las siguientes pertinentes regulaciones EG Maschinen Richtlinie 2006 42 EG Angewendete harmonisierte europ ische Normen Harmonised European standards applied Suivant les normes europ ennes D...

Page 24: ...KG www mato de Tel 49 0 6108 906 0 Benzstr 16 24 D 63165 M hlheim a M mato germany mato de Fax 49 0 6108 906 120 Qualit tsschmierger te High Quality Fluid Handling Products La Technologe de graissage...

Reviews: