background image

34 

                                                                                                                                                                                     

1812411-11  

 
Disclaimer 
 

All  information,  illustrations,  and  specifications  contained  in  this  user  manual  are  based  on  the  latest  information 
available at the time of printing. The right is reserved to make any changes at any time without obligation to notify any 
person or organization of such revisions or changes.  

Furthermore,  the  manufacturer,  or  its  sales  agents  are  not  liable  for  errors  contained  herein  or  for  incidental  or 
consequential damages (including lost profits) in connection with the furnishing, performance or use of this material. 

This user manual tells how to use and perform the required procedures during testing. Safe and effective use of this 
tester is very much dependent on the user following the normal practices and procedures outline in this manual. 

 
Warranty Information 
 

Limited Warranty 

This limited warranty covers defects in materials and workmanship for a period of two (2) years beginning the date 
the product is purchased by the end user and is subject to the following terms and conditions: 
 
1.  Within the warranty period, the manufacturer will repair or replace, at their option, any defective parts and return 

to the owner in good working condition.    

 

2.  Any repaired or replaced parts will be warranted for the balance of the original warranty or three months (3) 

months from the date of repair, whichever is longer. 

 

3.  This warranty only extends to the first owner and is not assignable or transferable to any subsequent owner. 

 

4.  Cost of delivery charges incurred for the repair of the product to and from the manufacturer will be borne by the 

owner.  

 

5.  This limited warranty covers only those defects that arise as a result of normal use and does not cover those 

that arise as a result of: 

 

Unauthorized modifications and repair. 

 

Improper operation or misuse. 

 

Accident or neglect such as dropping the unit onto hard surfaces. 

 

Contact with water, rain or extreme humidity. 

 

Contact with extreme heat. 

 

Cables that have broken, bent contact pins or subject to extreme stress or wear. 

 

Physical damage to the product surface including scratches, cracks or other damage to the display screen 
or other externally exposed parts. 
 

Limitations of Warranty 

 

Other than the foregoing limited warranty, the manufacturer does not make any other warranty or condition of 
any kind, whether expressed or implied. 

 

Any implied warranty of merchantability, or fitness for use shall be limited to the duration of the foregoing limited 
warranty. 

 

Otherwise, the foregoing 

limited warranty is the owner’s sole and exclusive remedy and is in lieu of all other 

warranties whether expressed or implied. 

 

The manufacturer or any  of its exclusive sales agents  shall  not be  liable for any  consequential or  incidental 
damages or losses arising from the use of this product. 

 

All warranty information, product features and specifications are subjected to change without prior notice. 

Summary of Contents for MBT2415

Page 1: ...on all 12V or 24V batteries and is able to perform four tests 1 Battery Test This test is intended only on 12V batteries The Analyzer clips red black have to be clamped onto the battery terminals When...

Page 2: ...ing its job properly Specifications Operating Voltage 9V 36V DC max Test Functions 12 Volts Battery test Starter test Alternator Diode ripple Grounding tests 24 Volts Starter test Alternator test Smar...

Page 3: ...d can cause severe burns if it comes in contact between power source and ground Always keep a fire extinguisher readily available and easily accessible in the workshop Working with Batteries Lead acid...

Page 4: ...ened to the battery terminal posts this may give inaccurate readings or inconsistent results Note This also applies to all other battery testing methods 5 During testing on the battery while it is sti...

Page 5: ...characters in one line and accommodates up to seven lines maximum To enter into this mode power ON the Analyzer by clamping on the battery terminals then after the beep press key twice 2 times then pr...

Page 6: ...ts engine OFF first and then switch ON the headlights for 30 seconds to remove the surface charge After the headlights are switched OFF let the battery rest for at least 1 minute to recover before tes...

Page 7: ...articulars Select The Analyzer will always begin in this mode Once entered the display will show Fig 14 as below To key in the particulars e g VIN vehicle registration numbers battery model testing da...

Page 8: ...perform Alternator Test or Grounding Test on the same car just select this function and it will update the results after each test in its memory and it can be retrieved for review later or to be print...

Page 9: ...y to move forward or key to move backward to the next page Once confirmed press key Then press again key one more time to delete the result This action allows user to double confirm before deleting th...

Page 10: ...Batteries AGM FLAT SPIRAL tests on Wet MF Maintenance Free Calcium Ca Calcium Ca AGM Flat or Spiral Plates Batteries EFB tests Start Stop or Enhanced Flooded Batteries GEL tests Gel Cell VRLA Batteri...

Page 11: ...ey to increase or decrease the original value shown on the display by 100 units Likewise use or key to increase or decrease the last two digits by 5 units for each press See Fig 25 below 12 Once the A...

Page 12: ...or After charge Fig 29 Selecting Before charge or After charge will determine final test results 16 To print out the results just press key on the Analyzer the printer will start printing Motorcycle...

Page 13: ...tester when purchased to get values to be keyed in Once the battery type SLI WET or AGM has been selected it will proceed to the display as shown below Fig 33 20 Press key and the display will show as...

Page 14: ...of Charge SOC of the tested battery which is 12 55V during open circuit condition By referring to the table below this battery is above 50 SOC 3 Battery Rating 180 CCA The battery capacity rated outp...

Page 15: ...100 CCA battery is still working Based on the Society of Automotive Engineers SAE in America CCA test is a manufacturing process control test applicable only on new fully charged batteries It does no...

Page 16: ...list provided basing on the JIS model number DIN Deutsches Industrie Normen Standard Basing on DIN the rating requires that at 0 F 18 C the 12V battery is able to deliver the number of amperes while...

Page 17: ...m is higher than 15 m limit Pressing the key at any moment will exit and return back to the main menu display Starter Test This test is only available in test and it actually checks the cranking effec...

Page 18: ...r the printer will start printing 5 Pressing the key will exit and return to the main menu screen Fig 42 Alternator Test This test is only available in test It checks the MAX and MIN charging voltages...

Page 19: ...a 24V system and vice versa if it is a 12V system 3 From the main MENU Fig 46 select by scrolling left using key Press key and the display will prompt you to select which type of Alternator Smart or N...

Page 20: ...Should be more than 25 2V Smart Alternator Charging 12V System No load MAX voltage should not exceed 16 2V and MIN voltage should be 12 4V Loaded Should be more than 12 0V 24V System No load MAX volta...

Page 21: ...cal load should be OFF as it sometimes slows down the idling speed of certain cars while it is ON thereby affecting the idling speed charging results 7 Press key and the display will change as shown i...

Page 22: ...able 0 5V 9 Continue from the previous test either Fig 55 56 or 57 the Analyzer will automatically proceed to diode ripple test The display will show as below Fig 58 10 While the engine is still runni...

Page 23: ...of the two batteries that provides the 12V for the operation If you had accidentally clamped onto a 24V battery output it will remind you with the display as shown below Fig 62 and Fig 63 In this cas...

Page 24: ...display will show Fig 68 which means that you need to press key to continue 4 When key is pressed it will start analyzing and the display will change to the screen below Fig 69 5 Once it has finished...

Page 25: ...5 Note The above Fig 75 indicates that the ground contact from the engine body to the battery is bad Check for rusted or corroded point of contacts If found dismantle it for cleaning or replace before...

Page 26: ...car battery or connected to a PC via the USB port using a USB cable 1 Once powered up the wakeup screen will display as follows Fig 77 Fig 78 2 Select View Test Report from Memory by scrolling with k...

Page 27: ...nable to provide Printing of the stored Test Results can be done while in View Test Results from Stored Memory Fig 81 86 To print just press key on the Analyzer the printer will start printing An exam...

Page 28: ...tall the previously installed driver first before reinstallation This time make sure that the Analyzer is not plugged in Step 1 You can install the driver from the CD provided or download from this li...

Page 29: ...tall A few seconds later the display will show as below that the installation has been completed Click OK tab to exit Once the software has been installed the icon will appear on the desktop Step 4 No...

Page 30: ...ause the Analyzer is already communicating with the PC Step 5 On the PC go to desktop display and look for icon Left click on the icon to open the program and the display page will show as below Add t...

Page 31: ...ug the Analyzer from the PC and repeat Step 4 and Step 5 If problem persists then select an alternate COM PORT individually from the dropdown list and click tab to see whether the Last Test Result wil...

Page 32: ...e saved in MS Office Word document format Set the paper size to A4 Use Scale To Fit to print on standard A 8 5x11 paper While in MS Office Word page go to Page Layout tab and right click display shows...

Page 33: ...nd keys together A few seconds later the display will change to Fig 96 as shown below and that completes the process Warning Performing the above procedures will erase all records from the tester Usin...

Page 34: ...r is longer 3 This warranty only extends to the first owner and is not assignable or transferable to any subsequent owner 4 Cost of delivery charges incurred for the repair of the product to and from...