SAE (The Society of Automotive Engineers) Standard.  

SAE has established Cold Cranking Amperes (CCA) rating for batteries as their standard. Therefore this rating 
is the same as CCA rating as mentioned above. 

 

IEC (International Electro technical Commission) Standard. 

IEC amperes rating require that at 0

F (-18

C), the number of amperes that the 12V battery can deliver while 

maintaining a voltage of at least of 8.4 Volts for 60 seconds during cranking. 

 

EN 1 (European Norms) Standard. 

EN 1 amperes rating require that at 0

F (-18

C), the number of amperes that the 12V battery can deliver while 

maintaining a voltage of at least 7.5 Volts for 10 seconds discharged at the rated current, followed by 10 seconds 
rest,  then  it  is  discharged  at  60%  of  the  original  current  for  further  73  seconds  to  give  an  equivalent  total 
discharge time at the lower current of 90 seconds still maintaining 7.5 Volts. 

 

EN 2 (European Norms) Standard. 

EN 2 amperes rating require that at 0

F (-18

C), the number of amperes that the 12V battery can deliver while 

maintaining a voltage of at least 7.5 Volts for 10 seconds discharged at the rated current, followed by 10 seconds 
rest,  then  it  is  discharged  at  60%  of  the  original  current  for  further  133  seconds  to  give  an  equivalent  total 
discharge time at the lower current of 150 seconds still maintaining 6.0 Volts. 

 

JIS# (Japanese Industrial Standard) 

JIS # amperes’ rating is based on Ampere Hours and is calculated using 20 hours rating. In this manual, it is 
using CCA ratings reference table list provided basing on the JIS model number.  

 

DIN (Deutsches Industrie Normen) Standard. 

Basing on DIN , the rating requires that at 0

F (-18

C), the 12V battery is able to deliver the number of amperes 

while maintaining a voltage of at least of 9.0 Volts for 30 seconds and 8.0 Volts for 150 seconds during cranking. 

 

CA (Cranking Amperes) / MCA (Marine Cranking Amperes) Rating.

 

This rating is the number of amperes that a new fully charged battery can delivery at 32

F (0

C) for 30 seconds, 

while maintaining a voltage of at least 7.2 Volts for a 12V battery during cranking.  
 

 

?? (Unknown) 

If you are not sure which ratings (CCA, EN, IEC, JIS or DIN) that the battery is based on, then choose this setting. 

It will show the bat

tery’s voltage (State of Charge), CCA and the Internal Resistance (m

) only.  

This selection can also be used to test 12V - Deep Cycle Batteries. An example of the results display is shown 
below (Fig.37): 

 

 

 

 

To determine the condition of the tested Deep  Cycle  Batteries, refer  to the 

Volts

 reading 

– State of Charge 

(

should not fall below 12.60V when fully charged for Lead Acid Batteries, 12.85V for Gel Batteries and 12.80V 

for AGM Batteries

) and the Internal Resistance [

Int. R

] of the tested battery should

 not be more 15 m

 

to be 

considered a good battery. 

7.  Batteries that have been left idle for long periods can still be tested with this Analyzer. To perform the test, 

just clamp the Analyzer clips on  the battery  terminals and it  will display  the screen (Fig.38 on following 
page) as shown if its voltage falls below the normal 12.0 volts. 
 

Note: Any battery whose voltage falls below 10.6V will be considered a shorted battery. 

Fig.37 

12.55   V 
    120  CCA 
18.91  m

 

 

State of Charge (SOC) 
Measured CCA (Power Available) 
Internal Resistance 

 

Summary of Contents for MBT2415

Page 1: ...on all 12V or 24V batteries and is able to perform four tests 1 Battery Test This test is intended only on 12V batteries The Analyzer clips red black have to be clamped onto the battery terminals When...

Page 2: ...ing its job properly Specifications Operating Voltage 9V 36V DC max Test Functions 12 Volts Battery test Starter test Alternator Diode ripple Grounding tests 24 Volts Starter test Alternator test Smar...

Page 3: ...d can cause severe burns if it comes in contact between power source and ground Always keep a fire extinguisher readily available and easily accessible in the workshop Working with Batteries Lead acid...

Page 4: ...ened to the battery terminal posts this may give inaccurate readings or inconsistent results Note This also applies to all other battery testing methods 5 During testing on the battery while it is sti...

Page 5: ...characters in one line and accommodates up to seven lines maximum To enter into this mode power ON the Analyzer by clamping on the battery terminals then after the beep press key twice 2 times then pr...

Page 6: ...ts engine OFF first and then switch ON the headlights for 30 seconds to remove the surface charge After the headlights are switched OFF let the battery rest for at least 1 minute to recover before tes...

Page 7: ...articulars Select The Analyzer will always begin in this mode Once entered the display will show Fig 14 as below To key in the particulars e g VIN vehicle registration numbers battery model testing da...

Page 8: ...perform Alternator Test or Grounding Test on the same car just select this function and it will update the results after each test in its memory and it can be retrieved for review later or to be print...

Page 9: ...y to move forward or key to move backward to the next page Once confirmed press key Then press again key one more time to delete the result This action allows user to double confirm before deleting th...

Page 10: ...Batteries AGM FLAT SPIRAL tests on Wet MF Maintenance Free Calcium Ca Calcium Ca AGM Flat or Spiral Plates Batteries EFB tests Start Stop or Enhanced Flooded Batteries GEL tests Gel Cell VRLA Batteri...

Page 11: ...ey to increase or decrease the original value shown on the display by 100 units Likewise use or key to increase or decrease the last two digits by 5 units for each press See Fig 25 below 12 Once the A...

Page 12: ...or After charge Fig 29 Selecting Before charge or After charge will determine final test results 16 To print out the results just press key on the Analyzer the printer will start printing Motorcycle...

Page 13: ...tester when purchased to get values to be keyed in Once the battery type SLI WET or AGM has been selected it will proceed to the display as shown below Fig 33 20 Press key and the display will show as...

Page 14: ...of Charge SOC of the tested battery which is 12 55V during open circuit condition By referring to the table below this battery is above 50 SOC 3 Battery Rating 180 CCA The battery capacity rated outp...

Page 15: ...100 CCA battery is still working Based on the Society of Automotive Engineers SAE in America CCA test is a manufacturing process control test applicable only on new fully charged batteries It does no...

Page 16: ...list provided basing on the JIS model number DIN Deutsches Industrie Normen Standard Basing on DIN the rating requires that at 0 F 18 C the 12V battery is able to deliver the number of amperes while...

Page 17: ...m is higher than 15 m limit Pressing the key at any moment will exit and return back to the main menu display Starter Test This test is only available in test and it actually checks the cranking effec...

Page 18: ...r the printer will start printing 5 Pressing the key will exit and return to the main menu screen Fig 42 Alternator Test This test is only available in test It checks the MAX and MIN charging voltages...

Page 19: ...a 24V system and vice versa if it is a 12V system 3 From the main MENU Fig 46 select by scrolling left using key Press key and the display will prompt you to select which type of Alternator Smart or N...

Page 20: ...Should be more than 25 2V Smart Alternator Charging 12V System No load MAX voltage should not exceed 16 2V and MIN voltage should be 12 4V Loaded Should be more than 12 0V 24V System No load MAX volta...

Page 21: ...cal load should be OFF as it sometimes slows down the idling speed of certain cars while it is ON thereby affecting the idling speed charging results 7 Press key and the display will change as shown i...

Page 22: ...able 0 5V 9 Continue from the previous test either Fig 55 56 or 57 the Analyzer will automatically proceed to diode ripple test The display will show as below Fig 58 10 While the engine is still runni...

Page 23: ...of the two batteries that provides the 12V for the operation If you had accidentally clamped onto a 24V battery output it will remind you with the display as shown below Fig 62 and Fig 63 In this cas...

Page 24: ...display will show Fig 68 which means that you need to press key to continue 4 When key is pressed it will start analyzing and the display will change to the screen below Fig 69 5 Once it has finished...

Page 25: ...5 Note The above Fig 75 indicates that the ground contact from the engine body to the battery is bad Check for rusted or corroded point of contacts If found dismantle it for cleaning or replace before...

Page 26: ...car battery or connected to a PC via the USB port using a USB cable 1 Once powered up the wakeup screen will display as follows Fig 77 Fig 78 2 Select View Test Report from Memory by scrolling with k...

Page 27: ...nable to provide Printing of the stored Test Results can be done while in View Test Results from Stored Memory Fig 81 86 To print just press key on the Analyzer the printer will start printing An exam...

Page 28: ...tall the previously installed driver first before reinstallation This time make sure that the Analyzer is not plugged in Step 1 You can install the driver from the CD provided or download from this li...

Page 29: ...tall A few seconds later the display will show as below that the installation has been completed Click OK tab to exit Once the software has been installed the icon will appear on the desktop Step 4 No...

Page 30: ...ause the Analyzer is already communicating with the PC Step 5 On the PC go to desktop display and look for icon Left click on the icon to open the program and the display page will show as below Add t...

Page 31: ...ug the Analyzer from the PC and repeat Step 4 and Step 5 If problem persists then select an alternate COM PORT individually from the dropdown list and click tab to see whether the Last Test Result wil...

Page 32: ...e saved in MS Office Word document format Set the paper size to A4 Use Scale To Fit to print on standard A 8 5x11 paper While in MS Office Word page go to Page Layout tab and right click display shows...

Page 33: ...nd keys together A few seconds later the display will change to Fig 96 as shown below and that completes the process Warning Performing the above procedures will erase all records from the tester Usin...

Page 34: ...r is longer 3 This warranty only extends to the first owner and is not assignable or transferable to any subsequent owner 4 Cost of delivery charges incurred for the repair of the product to and from...

Reviews: