Page | - 32 -
© Copyright Mastip Technology Limited. Information subject to alteration. V1.01 www.mastip.com
Temperature Controller METICOM CTI Series
6.5.3 Engineers or Administrators Login Status
●
Change General and Engineer’s parameter value: click it to call up small keyboard.
●
Set output percent in Manual mode: click the value of Manual to call up small keyboard.
●
Run or Stop this zone: touch [
Run
] / [
Stop
].
●
Turn off or turn on this zone: touch [
OFF
] / [
ON
]
●
Change Control mode of this zone (in running state): touch [
Auto
] or [
Manual
].
●
Activate Boost function (fast heating speed): touch [
Boost
], and the power output
percent will be added 20% (max.100%) for 15s.
●
Start Auto-Tune this zone: touch .
●
Select background color for this zone: touch [
Color
].
●
Back to main interface: touch [
Exit
].
6.6 Graph Display
Touch [
Graph
] on the main interface to enter the Present Curve Display Screen.
You can select 6 zones to view the real-time curve.
And you can touch [
History
] on this screen to enter the History Curve Display.