Page | - 15 -
© Copyright Mastip Technology Limited. Information subject to alteration. V1.01 www.mastip.com
Temperature Controller METICOM CTI Series
(
Icon Button Mode
)
[
Run
] (green)/[
Stop
] (red): Run or Stop temperature & valve gate control of all zones.
In Stop mode, shows Run; and in Run mode, shows Stop.
[
Auto
]: Place the sequential valve gate control of all zones in Auto mode.
[
Manual
]: Place the sequential valve gate control of all zones in Manual mode.
In this mode, each valve gate can be opened or closed by manual.
[
Temp
]: Shift to the temperature control interface.
[
Graph
]: View the open & close sequence setting of all valve gates.
[
Group
]: Enter the group/global setting, pattern/mold files management, and language selected .
[TEST]: Used to simulate the trigger signal to test all valve gates control.
[
Login
]/[
Logout
]: Log in/out the system to achieve the different security authority.
⑴
Gate Number.
⑵
Working Status.
⑶
Valve Gate Status:
Open,
Close
or
OFF
(when zone is set to off).
⑷
Control Mode: Auto or
Manual
.
In Manual mode, touch it to open/close gate.
⑸
Start Trigger Indicator: green–off, red–on.
⑹
Output signal: 24V or 220V (selected on modules)
⑺
Screw position: unit is mm or inch,
selected in screw position’s calibration.
4.2 USB Port
The USB port on the CTI series is intended to be used to copy mold setup files to and from the system.
The screen for importing or exporting mold setups is displayed in the Group Setup Screen.
These mold setup files can be copied to other CTI controllers that support the same file type.
The USB port is also be used to export the historical data record (in csv format) from the system. The
screen for exporting data record is displayed in the History Data Curve Screen.