Page | - 27 -
© Copyright Mastip Technology Limited. Information subject to alteration. V1.01 www.mastip.com
Temperature Controller METICOM CTI Series
6.4 Group Setting & Mold Patterns & Language selection
Touch [
Group
] on the main interface, and then you can enter the Global Config & Pattern
Management Screen.
6.4.1 Group Setting
Parameters for all zones can be changed at once using Global Config, or parameters for just zones
with same background color can be changed at once by using Group Config.
6.4.1.1 Global Config
Parameters for all zones can be set all together.
1) Click the parameter value to be set, and then the keyboard will appear.
2) Input the required value.
3) Click [OK] to complete the setting.
NOTE: I
f there is no response when you click the parameter’s value, it means this parameter cannot be
changed or the authority security is not enough.
6.4.1.2 Group Config
Parameters for zones with the same background color can be set all together.
Comment: To set the background color of each zone, please refer to 6.5.3
1) Click [Group Config], the background color window will appear.
2) Select the background color of zones you want to set parameters, the setting page will appear.