OPERATION OF DATACONTROL
12
December 2008 / USB Interface for Solar ChargeMaster / EN
Click on button “Current Values” to see the current status of system as shown in Figure 5
-
7.
Figure 5-7: Current data of the Solar ChargeMaster
The table explains the Current Value variables
Variable
Description
Other information
SCM Version
Version number of the SCM-N 20/40 Controller
Hours since night
began
Number of hours since dusk, see section 5.9.
Length of the last
night in hours
Last night length, calculated by the Solar ChargeMaster
Temperature in °C
Battery
temperature, measured by the sensor
Battery information
Battery voltage in V
Battery voltage at the moment
Battery state of charge
(SOC) in %
Battery voltage in % of the maximum voltage, depending on battery type setting
End of charge voltage
Battery voltage in V at the end of charge.
Charge mode
BOOST means 14.4V/28.8V, EQUAL means 14.8V/29.6V
Present Current data
Nominal Current
Nominal current of the Solar ChargeMaster, i.e. 20 A or 40 A.
PV current in A
Current of energy generated by the PV cells.
Load current in A
Current drawn by the loads connected to the Solar ChargeMaster
PV Ah this day
Total of amperehours generated by the PV system this day.
Load Ah this day