model no. 062-3538-6 | contact us 1-800-689-9928
4
QUICK ST
AR
T GUIDE
DISCHARGE PLUMBING
To install the discharge plumbing
and check valve on the pump:
A. Use non-stick tape —
NOT pipe
joint compound.
B. Tighten the pipe into the pump.
C. Install the check valve as close to
the pump as possible.
D. Drill an 1/8” (3 mm) anti-airlock
hole as shown. The hole must be in
the sump.
2
INSERTING THE PUMP
Place the pump in the sump,
making sure that nothing interferes
with switch operation.
3
SUMP REQUIREMENTS
Pit must be covered. It is usually
10” (25.4 cm) in diameter and
14” (35.6 cm) deep.
Install on a hard surface: brick,
cement, or concrete block;
not sand, clay, or gravel.
1
1 1/4" (3.2 cm) or
1 1/2" (3.8 cm)
Discharge Pipe
Check Valve
1/8" (3 mm)
Anti-airlock Hole
PVC Threaded
Adaptor
Sump Pit
14"
(35.6 cm)
depth
10" (25.4 cm) diameter