MasterCraft 062-3538-6 Instruction Manual Download Page 17

headline bars

continuation tabs

notes

warnings

17

This Mastercraft product is guaranteed for a period of 

two (2) year

 from the date of original retail purchase, against 

defects in materials and workmanship.
Subject to the conditions and limitations described below, this product, if returned to us with proof of purchase within 
the stated warranty period and if covered under this warranty, will be repaired or replaced (with the same model, or one 
of equal value or specification), at our option. We will bear the cost of any repair or replacement and any costs of labour 
relating thereto.

These warranties are subject to the following conditions and limitations :

a. a bill of sale verifying the purchase and purchase date must be provided;
b. this warranty will not apply to any product or part thereof which is worn or broken or which has become inoperative 

due to abuse, misuse, accidental damage, neglect or lack of proper installation, operation or maintenance (as 
outlined in the applicable owner’s manual or operating instructions) or which is being used for industrial, professional, 
commercial or rental purposes;

c. this warranty will not apply to normal wear and tear or to expendable parts or accessories that may be supplied with 

the product which are expected to become inoperative or unusable after a reasonable period of use;

d. this warranty will not apply to routine maintenance and consumable items such as, but not limited to, tune-ups or 

adjustments;

e. this warranty will not apply where damage is caused by repairs made or attempted by others (i.e., persons not 

authorized by the manufacturer);

f.  this warranty will not apply to any product that was sold to the original purchaser as a reconditioned or refurbished 

product (unless otherwise specified in writing);

g. this warranty will not apply to any product or part thereof if any part from another manufacturer is installed therein or 

any repairs or alterations have been made or attempted by unauthorized persons;

h. this warranty will not apply to normal deterioration of the exterior finish, such as, but not limited to, scratches, dents, 

paint chips, or to any corrosion or discolouring by heat, abrasive and chemical cleaners; and

i.  this warranty will not apply to component parts sold by and identified as the product of another company, which shall 

be covered under the product manufacturer’s warranty, if any.

Additional Limitations

This warranty applies only to the original purchaser and may not be transferred. Neither the retailer not the manufacturer 
shall be liable for any other expense, loss or damage, including, without limitation, any indirect, incidental, consequential 
or exemplary damages arising in connection with the sale, use or inability to use this product.

Notice to Consumer

This warranty gives you specific legal rights, and you may have other rights, which may vary from province to province. 
The provisions contained in this warranty are not intended to limit, modify, take away from, disclaim or exclude any 
statutory warranties set forth in any applicable provincial or federal legislation.

Made in China

Imported by 
Mastercraft Canada Toronto, Canada M4S 2B8

W

ARRANTY

Summary of Contents for 062-3538-6

Page 1: ...s IMPORTANT Please read this manual carefully before running this submersible sump pump and save it for reference INSTRUCTION MANUAL Submersible SUMP PUMP Model No 062 3538 6 ...

Page 2: ...headline bars continuation tabs notes warnings headline bars continuation tabs notes warnings ...

Page 3: ...al contains important safety and operating instructions Read all instructions and follow them with use of this product TABLE OF CONTENTS Quick Start Guide 4 Technical Specifications 6 Safety Guidelines 8 Key Parts Diagram 11 Assembly Preparation 12 Assembly Instructions 13 Operating Instructions 14 Maintenance 15 Troubleshooting 16 Warranty 17 TABLE OF CONTENTS ...

Page 4: ... as close to the pump as possible D Drill an 1 8 3 mm anti airlock hole as shown The hole must be in the sump 2 INSERTING THE PUMP Place the pump in the sump making sure that nothing interferes with switch operation 3 SUMP REQUIREMENTS Pit must be covered It is usually 10 25 4 cm in diameter and 14 35 6 cm deep Install on a hard surface brick cement or concrete block not sand clay or gravel 1 1 1 ...

Page 5: ...nsion cord with a sump pump Regularly inspect pump inlet and clean away any debris QUICK START GUIDE COMPLETING THE PLUMBING Finish installing the necessary plumbing Follow the glue manufacturer s instructions for curing time PLUGGING IN THE PUMP Plug the pump into a 15 A circuit The circuit should be GFCI protected and dedicated to the sump pump 4 VERIFYING OPERATION Check the pump s operation by...

Page 6: ...ermanent split capacitor PSC Motor protection Auto reset thermal overload protection in motor Construction material Stainless steel motor housing cast iron volute plastic impeller Motor NEMA L torque curve oil filled squirrel cage induction class B insulation Maximum flow 4200 U S GPH 15 899 L hr Maximum head height 29 8 8 m MOTOR AND ELECTRICAL SKU number 062 3538 6 HP 1 2 Power 115 V AC Hz 60 RP...

Page 7: ... litres per hour 4200 15 899 4000 15 142 3600 13 627 3200 12 113 2400 9 084 1200 4 542 DIMENSIONS PERFORMANCE CHART Friction loss in piping not included in measurement 7 5 8 19 3 cm 4 10 2 cm 2 7 8 7 3 cm 10 1 16 25 6 cm 12 5 8 32 1 cm 8 1 2 21 6 cm 3 1 2 8 9 cm 3 7 6 cm 8 5 8 21 9 cm 3 15 16 10 cm ON OFF ...

Page 8: ...ene ethanol etc Do not use in the presence of flammable or explosive vapours Using this pump with or near flammable liquids can cause an explosion or fire resulting in property damage serious personal injury and or death Risk of electric shock Never remove the ground terminal on the three pronged power plug of the pump as the ground terminal is designed for protection Do not adjust any electrical ...

Page 9: ...mel paint All surfaces should then be sprayed with a rust inhibiting oil Pump should be stored in its original shipping container On initial start up rotate impeller by hand to ensure seal and impeller rotate freely INSTALLATION DISCHARGE Discharge piping should be as short as possible A check valve is recommended for each pump being used The check valve is used to prevent backflow into the sump E...

Page 10: ...and record at the end of the manual for future reference INSULATION TEST Before the pump is put into service an insulation megger test should be performed on it The ohm values as well as the volts and amps should be recorded PUMP DOWN TEST After the pump has been properly wired and lowered into the basin sump or lift station it is advisable to check the system by filling with liquid and allowing t...

Page 11: ... KEY PARTS DIAGRAM PARTS LIST No Description Qty 1 Power cord 1 2 Carry handle 1 3 Motor cap 1 4 Motor housing 1 No Description Qty 5 1 1 4 3 2 cm adaptor 1 6 Pump outlet 1 7 Float switch 1 7 1 5 6 3 4 2 ...

Page 12: ...ng salt water or brine Use with waterfalls fountains salt water or brine will void warranty Do not use where water recirculates Not designed for use as a swimming pool drainer Flat head screwdriver Threaded adaptor pipe to pump 1 1 4 3 2 cm or 1 1 2 3 8 cm check valve 1 1 4 3 2 cm or 1 1 2 3 8 cm ABS or PVC pipe Hacksaw Cable ties Safety goggles Tape measure Cross head screwdriver Channel lock pli...

Page 13: ... be 14 35 6 cm Construct the sump pit of tile concrete steel or plastic Check local codes for approved materials and for proper installation Install the pump in a pit so that the switch operating mechanism has maximum possible clearance The pump should not be installed on clay earth or sand surfaces Clean the sump pit of small stones and gravel which could clog the pump Keep the pump inlet screen ...

Page 14: ...or has cooled sufficiently the switch will reset automatically and restart the motor If the protector trips repeatedly the pump should be removed and checked Low voltage long extension cords clogged impeller very low head or lift a plugged or frozen discharge pipe etc could cause the protector to trip The pump will not remove all water OPERATION DANGER Risk of electric shock fire or serious injury...

Page 15: ...the impeller 2 Reassemble the pump CARE AND CLEANING DO DO NOT When the power is disconnected inspect the pump suction screen and remove all debris then plug the pump back into the grounded GFCI outlet Do not disassemble the motor housing This motor has NO repairable internal parts Do not lift up the pump by the power cord 1 2 5 4 3 CAUTION Always use the handle to lift the pump Never use the powe...

Page 16: ... pumps little or no water The screen is blocked Debris is caught in the impeller or discharge The impeller is loose on the shaft or the impeller is broken Clean the screen Remove the debris Reassemble the impeller or replace the impeller The pump starts and stops too often There is a backflow of water from the piping or the check valve is leaking The float switch is stuck Install a check valve or ...

Page 17: ... damage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer f this warranty will not apply to any product that was sold to the original purchaser as a reconditioned or refurbished product unless otherwise specified in writing g this warranty will not apply to any product or part thereof if any part from another manufacturer is installed therein or any re...