MAINTENANCE
TO CLEAN A PUMP CLOGGED WITH DEBRIS:
•
Unplug the pump from electrical power.
•
Unscrew the stainless screws (5), the seal plate (4) and gasket (3).
•
Use a flat-head screwdriver to hold the shaft (1), then turn the impeller (2) counter-
clockwise to release the impeller (2).
•
Remove debris from around the shaft (1) and on/under the impeller (2).
•
Reassemble the pump.
CARE AND CLEANING
DO
DO NOT
When the power is disconnected,
inspect the pump suction screen and
remove all debris, then plug the pump
back into the grounded (GFCI) outlet.
Do not disassemble the motor housing.
This motor has NO repairable internal
parts.
Do not lift up the pump by the power cord.
1
2
5
4
3
CAUTION!
• Always use the handle to lift the pump. Never use the power cord to lift the pump.
To avoid skin burns, unplug the pump and allow time for it to cool after periods
of extended use.