Physical installation
9
Physical installation
Warning! Read “Safety Information” on page 3 before installing the LC Plus.
Warning! The safety and suitability of lifting equipment, installation location, anchoring method,
mounting hardware and electrical installation is the responsibility of the installer. All local
safety regulations and legal requirements must be observed when installing and connecting the
LC Plus.
Warning! Installation must be carried out by qualified professionals only. Contact your Martin
supplier for assistance if you have any questions about how to install this product safely.
Warning! The surface of the heatsink in the base of the panel can become hot during normal
operation. Install so as to prevent accidental contact by members of the public.
Warning! Use two conical couplers to fasten a panel to a supporting structure or to another
panel. When lifting a panel, use two conical couplers as attachment points for lifting gear. Do
not use only one conical coupler or any other method to suspend, lift or attach panels. Do not
use the ventilation holes in the top rail or the LED tubes as attachment points.
Warning! Secure every panel with two safety cables that are approved for the weight they secure
and installed as described in this manual.
Warning! When stacking panels one on top of another or suspending panels one from another,
do not exceed the limits given in Figure 3. If an installation needs to be taller than the limits
given in Figure 3, additional support points must be provided to bear the weight of the
additional panels.
Warning! When stacking panels, secure them so that they cannot tip or fall.
The LC Plus can be installed in a standing position alone or stacked, flown in a vertical curtain or
suspended in any orientation from a truss or supporting structure.
Standing installation
See Figure 3. One vertical stack with LC Plus 1140 panels resting on each other may contain a maximum of
nine LC Plus 1140 panels stacked upright or eight LC Plus 1140 panels stacked on their sides.
Stacked
upright
Stacked
on side
Suspended
upright
Suspended
on side
LC Plus 1140
Max. 9
Max. 8
Max. 8
Max. 8
LC Plus 2140
Max. 7
Max. 5
Max. 6
Max. 6
Figure 3: Safety limits for stacking and suspending attached panels