background image

 22

LC Plus user manual

Service and maintenance

Warning! Disconnect the panel from power and ensure that all connectors are sealed either 
with their corresponding cable connectors or with their caps, or isolate the entire 
distribution circuit from power before cleaning. Refer any service operation not described 
below to service technician approved by Martin Professional. Removing any cover or LED 
tube may cause a safety risk or unsatisfactory performance and will invalidate the product 
warranty.

The user will need to carry out periodic cleaning, and it is also possible for the user to update the LC Plus 
firmware quickly and easily from the P3-100 System Controller. All other service operations must be carried 
out by Martin Professional or its approved service agents.

Installation, on-site service and maintenance can be provided worldwide by the Martin Professional Global 
Service organization and its approved agents, giving owners access to Martin’s expertise and product 
knowledge in a partnership that will ensure the highest level of performance throughout the product’s 
lifetime. Please contact your Martin supplier for details.

It is Martin policy to apply the strictest possible calibration procedures and use the best quality materials 
available to ensure optimum performance and the longest possible component lifetimes. However, LEDs are 
subject to wear and tear over the life of the product, resulting in gradual changes in color and overall 
brightness over many thousands of hours of use. The extent of wear and tear depends heavily on operating 
conditions and environment, so it is impossible to specify precisely whether and to what extent LED 
performance will be affected. However, you may eventually need to ask Martin Professional to replace LED 
tubes if LED characteristics are affected by wear and tear after an extended period of use and if you require 
panels to perform within very precise optical and color parameters.

The fuses marked F1 and F2 on the PCB may only be replaced by Martin Service or its authorized agents. 
These fuses must be 10 A/250 V, HBC type.

The LEDs will not be affected by weather conditions as they are sealed inside acrylic tubes. However, the 
outer surfaces of the acrylic tube will be exposed to the elements, dirt, dust, etc.

Cleaning

Do not use abrasive, caustic or solvent-based products for cleaning, as they can cause surface damage. 

To clean an LC Plus panel:

1. Vacuum or gently blow away dust and loose particles from the heatsink fins on the base of the panel with 

low-pressure compressed air. 

2. Wipe the outside of the LED tubes with a soft, lint-free cloth dampened with a solution of water and 

detergent or auto shampoo. Apply gentle pressure only.

Installing new software

It may be necessary to upload new software to the LC Plus if the product appears to have a software-related 
fault or if you want to update to a newer software version. Software updates are available from Martin and 
can be installed from the P3-100 System Controller over the P3 link. See the P3-100 System Controller user 
manual for instructions for this procedure.

Summary of Contents for LC PLUS

Page 1: ...LC Plus LED Video Display Panel Installation and Safety Manual TM...

Page 2: ...ss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the Martin name and all other trad...

Page 3: ...d fault earth fault protection Connect LC Plus panels to AC power using only 16 A rated industrial Type B power plugs and socket outlets that comply with IEC 60309 or a comparable national standard an...

Page 4: ...any other method of attachment than those described in this manual When stacking panels on top of each other fasten panels securely to prevent them from tipping or falling and do not stack more than...

Page 5: ...9 Flying from a truss bar or other structure 10 AC power 12 Power and fuses 12 Power connection 13 P3 communication link 16 Planning the P3 link 16 Connecting the P3 link 18 Configuration and testing...

Page 6: ...ol panel and LED display See Using the control panel and control panel display on page 19 for details D Power input connector Used to supply power to the panel Accepts an Amphenol IP67 rated power inp...

Page 7: ...henol IP67 rated ruggedized threaded locking power connectors Prolyte CCS6 conical coupler system for fast installation For the latest firmware updates documentation and other information about this a...

Page 8: ...andard Martin LC Series Important Do not throw away the protective shock absorbing materials from the flightcase when you unpack panels The protective materials will be needed when panels are repacked...

Page 9: ...end lift or attach panels Do not use the ventilation holes in the top rail or the LED tubes as attachment points Warning Secure every panel with two safety cables that are approved for the weight they...

Page 10: ...suspended in an upright position and when suspended on their sides An unlimited number of curtains of panels may be installed alongside each other To fly panels from a rig or other structure 1 Check t...

Page 11: ...r the panel above so that if a rigging clamp or conical connector fails the weight of the panels will be held by the vertical columns and the blocks the columns are anchored in and not by the panel ba...

Page 12: ...easily accessible so that power to the LC Plus can easily be shut down or disconnected if necessary Important Connect the panels in the installation and the P3 controller to AC mains power at the same...

Page 13: ...nt power cables with Amphenol connectors installed are available from your Martin supplier The supplied power cables can be replaced with cables from other sources but replacement cables must be 3 con...

Page 14: ...trands at the end of each conductor to strengthen them 5 Fasten the conductors in the cable into the screw terminals in the male or female contact insert as follows When installing an Amphenol C016 se...

Page 15: ...309 or a comparable national standard and is rated 16 A minimum and use corresponding power outlet sockets Follow the plug and socket manufacturer s instructions and all locally applicable laws and el...

Page 16: ...utput can be used as a video source P3 link requirements in large installations A single P3 100 system controller can drive up to 400 LC Plus 2140 panels up to 800 LC Plus 1140 panels or any combinati...

Page 17: ...agram of P3 system connections DVI Analog video Analog video Monitor Mouse Keyboard P3 100 System Controller P3 signal 1GB Ethernet switch required 1GB Ethernet switch required 100 m Max 50 panels per...

Page 18: ...s not matter which port you use as both P3 connectors can be used for input and output In outdoor or wet locations an IP67 rated Amphenol RJF RB 6 housing must be installed on the RJ 45 plug 2 Continu...

Page 19: ...Plus panel is powered on The control panel is used as follows To enter the control menus see Table 5 hold MENU pressed in for one second The red status LED at the bottom right of the panel will flash...

Page 20: ...ation Action required Blue Constant Busy e g booting up or writing to flash memory Wait a moment for normal operation to be resumed Red Constant Error The panel has encountered a fatal error and can n...

Page 21: ...the original factory programmed firmware Note that performing a factory reboot will only cause the panel to boot the factory firmware once At the next power cycle or reset a normal reboot will be car...

Page 22: ...r and overall brightness over many thousands of hours of use The extent of wear and tear depends heavily on operating conditions and environment so it is impossible to specify precisely whether and to...

Page 23: ...evice tested and serviced All panels and or monitor screen display video incorrectly or do not display video at all Incorrect video input or panel settings on P3 100 System Controller Check settings P...

Page 24: ...00 processor Gamma curve selection and adjustment Yes integrated in P3 100 processor Real time panel content remapping Yes integrated in P3 100 processor P3 Signal Protocol Signal type Gigabit Etherne...

Page 25: ...ts made at nominal voltage with all LEDs at full intensity Allow for a deviation of 10 Thermal Cooling Convection Maximum ambient temperature Ta max 50 duty cycle full white 1 sec on 1 sec off 40 C 10...

Page 26: ...conical coupler floor mounting option with hole for spigot length 44 mm P N 21021152 Half conical coupler floor mounting option with hole for spigot length 63 mm P N 21021153 Half conical coupler flo...

Page 27: ......

Page 28: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: