background image

Control data 

Any device that outputs the DMX512 (1990) data protocol (including the one that may already be 
controlling your Atomic 3000 DMX strobe) can be used to control the Atomic Colors. ‘DMX’ is 
an industry standard data protocol, which allows up to 512 channels to be controlled through one 
serial data link. These 512 channels may be used by up to a maximum of 32 devices on only one 
cable run by ‘daisy-chaining’ the devices together.  
 
To work on the DMX system, each device is assigned a control address, also known as the start 
channel, which is the first channel used by that device, to receive instructions from the controller. 
The Atomic Colors uses 1, or 2 DMX channels depending on which control mode it is set for. 
The first DMX channel (start channel) controls the movement of the gel string, and the second 
channel, if selected, allows for remote control of the cooling fan speed. Details of the address 
setting procedure are given in Section 6 of this manual. 

 

Cables 

The power supply combines the control data and low voltage power into one XLR-4 cable that is 
then distributed to the fixture(s). One 5M (16.4 ft) XLR 4-pin cable is supplied with each fixture. 
The power supply connects to the DMX data link with 3 or 5-pin XLR cables.  
 
The type of cable used in this system has specific design requirements. Failure to use the correct 
type of cable can lead to malfunctions and/or damage to the system. Further details about cable 
construction are shown later in this section.  

Atomic Colors User Manual                           Preparation for use 

7

Summary of Contents for Atomic Colors

Page 1: ...Atomic Colors user manual...

Page 2: ...ined 2003 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Pr...

Page 3: ...ETY INFORMATION 4 INTRODUCTION 5 PREPARATION FOR USE 6 MOUNTING THE UNIT 9 CONNECTING THE UNIT 10 OPERATING THE UNIT 14 CHANGING THE GEL STRING 20 SERVICE 24 SPECIFICATIONS 25 Atomic Colors User Manua...

Page 4: ...at no objects or items are near the front aperture or can get trapped in the roller mechanism Make sure the power supply for the Atomic Colors is connected and switched on before operating the Atomic...

Page 5: ...size of power supply required is dependant on how many Atomic Colors you are using Eight Atomic Colors for example can be driven with a standard 8 unit scroller power supply The scroller power supply...

Page 6: ...02 and MPU 08 will function on any standard worldwide voltage frequency electrical supply You may need to attach a plug on the mains cable for power supply To install a plug on the mains lead The main...

Page 7: ...X channels depending on which control mode it is set for The first DMX channel start channel controls the movement of the gel string and the second channel if selected allows for remote control of the...

Page 8: ...w Please take care when constructing these cables A high percentage of problems are a direct result of poor cable construction Detail of connector wiring typical The correct wiring between male and fe...

Page 9: ...trobe as shown with the top hooks resting on the loose Taptite screws Align the lower front screw holes and replace the lower front screws 5 Tighten all screws 6 Rig Atomic 3000 DMX Colors fixture and...

Page 10: ...evices Ensure that all cables are securely fixed and do not present a safety hazard of any sort MPU 02 MPU 08 Power Supplies The MPU 02 and MPU 08 power supplies are specifically designed for use with...

Page 11: ...he power supply For more information on building a data link please refer to the Atomic DMX 3000 user manual Continue daisy chaining the DMX link by connecting the 5 pin DMX thru socket on the power s...

Page 12: ...Atomic Colors fixture 1 to the XLR 4 input on the Atomic Colors fixture 2 5 Repeat step 4 until you have a maximum of four Atomic Colors fixtures connected together 6 Connect the XLR 4 output on the...

Page 13: ...System connection diagram using the MPU 08 power supply For clarity only the Atomic Colors are shown Atomic Colors User Manual Connecting the unit 13...

Page 14: ...ay it is set up and the value of the DMX signal that the unit is receiving Push Button Operation Use the ACTION RECALL button to scroll through the different modes of operation Use the UP or DOWN butt...

Page 15: ...hrough 180 by pressing and holding the ACTION RECALL button then pressing the DOWN button Display Blank The display can be set to auto blackout after short time This is selected through the mode menu...

Page 16: ...the gel string Second DMX Channel Channel Level Dec Channel Level Speed Level Fan Speed 00 61 0 24 Fn4 62 127 25 49 Fn3 128 190 50 74 Fn2 191 255 75 100 Fn1 Fastest Slowest Gel saver GL Toggle the gel...

Page 17: ...d the ACTION RECALL button and press the UP button for 1 second The Factory default settings are Fan Speed Gel Saver Gel Speed Display Light activated Fan Display Flip Fn4 fast GL1 On SP1 normal dP1 O...

Page 18: ...off the gel saving mode Press UP or DOWN once to switch between on 1 and off 0 Note Ensure that the gel is centered by channel DMX value before implementing this mode or the next color may show throu...

Page 19: ...el Level Dec Channel Level Speed Level Fan Speed See notes below 00 61 0 24 Fn4 62 127 25 49 Fn3 128 190 50 74 Fn2 191 255 75 100 Fn1 Fastest Slowest Important notes 1 Please note that over time the g...

Page 20: ...top before attaching it to the anchors New users are recommended to use the manual loading method until they become familiar with the procedure When installing a gel string always start by applying th...

Page 21: ...ft Use small pieces of flat back tape 25mm 1 to secure the gel to the TUR hubs on either side top and bottom 3 Press the DOWN push button to advance the gel string onto the TUR 4 Continue this process...

Page 22: ...Installation of a gel string Atomic Colors User Manual Changing the gel string 22...

Page 23: ...Gel string construction Atomic Colors User Manual Changing the gel string 23...

Page 24: ...lengths are too long No cable return line Check all scroller speed settings Check the cable length and configuration Ensure there is a cable return line in the system Units have dim display indicator...

Page 25: ...ess 0 075 0 125mm 0 003 0 005 in For the best results use gel strings supplied by your dealer Gel frame capacity 2 11 gel frames Construction Housing Steel Finish Black electrostatic powder coat Insta...