background image

 

 

 

S

AFETY INFORMATION

 

1

 
 
 

 

Warning:   This product is for professional use only!  

        It is not designed for household use. 

 

This product is designed exclusively for use with the Martin Atomic 3000 DMX unit. Use the 
device only as intended.    
The Atomic 3000 DMX presents risks of lethal or severe injury due to fire and heat, electric 
shock, ultraviolet radiation, and falls. Flashing light is also known to trigger epileptic seizures in 
persons who are photosensitive. Please review the important safety information in the Atomic 
3000 DMX user manual. 

Read this manual

 before powering or installing the fixtures, follow the safety precautions listed 

below and observe all warnings in this manual. 
If you have questions about how to operate the fixtures safely, please contact your Martin dealer 
or call the Martin 24-hour service hotline at +45 70 200 201. 

 

Atomic Colors: Safety instructions. 
 

Before using this unit please read this manual completely, 

and refer to the user manual for Atomic 3000 DMX strobe.

 

General 

 

• 

Read this manual fully before starting to use the unit. 

• 

Ensure that no objects or items are near the front aperture, or can get trapped in the roller 
mechanism. 

• 

Make sure the power supply for the Atomic Colors is connected and switched on, 

before 

operating the Atomic strobe.

 

 

To guard against falls 

 

• 

When fitting the unit to the Atomic 3000DMX, ensure all screws are thoroughly re-tightened. 

• 

When rigging the unit, use the safety wire attached to the unit as a means of secondary 
attachment. 

Note: This safety wire is designed solely for use with the Atomic Colors unit. Use a 
separate safety wire for Atomic 3000DMX strobe, and any other pieces of equipment. 

• 

When suspending the fixture above ground level, verify that the structure can hold at least 10 
times the weight of all installed devices. 

• 

Verify that all external covers and rigging hardware are securely fastened and use an 
approved means of secondary attachment such as a safety cable. 

• 

Block access below the work area whenever installing or removing the fixture. 

 

To guard against epileptic seizure 

 

• 

Do not operate the fixture near stairways. 

• 

Provide advance notice that strobe lighting is in use. 

• 

Avoid extended periods of continuous flashing, particularly at frequencies of 10 to 20 flashes 
per second, or with the color red. 

Atomic Colors User Manual                         Safety Information 

4

Summary of Contents for Atomic Colors

Page 1: ...Atomic Colors user manual...

Page 2: ...ined 2003 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Pr...

Page 3: ...ETY INFORMATION 4 INTRODUCTION 5 PREPARATION FOR USE 6 MOUNTING THE UNIT 9 CONNECTING THE UNIT 10 OPERATING THE UNIT 14 CHANGING THE GEL STRING 20 SERVICE 24 SPECIFICATIONS 25 Atomic Colors User Manua...

Page 4: ...at no objects or items are near the front aperture or can get trapped in the roller mechanism Make sure the power supply for the Atomic Colors is connected and switched on before operating the Atomic...

Page 5: ...size of power supply required is dependant on how many Atomic Colors you are using Eight Atomic Colors for example can be driven with a standard 8 unit scroller power supply The scroller power supply...

Page 6: ...02 and MPU 08 will function on any standard worldwide voltage frequency electrical supply You may need to attach a plug on the mains cable for power supply To install a plug on the mains lead The main...

Page 7: ...X channels depending on which control mode it is set for The first DMX channel start channel controls the movement of the gel string and the second channel if selected allows for remote control of the...

Page 8: ...w Please take care when constructing these cables A high percentage of problems are a direct result of poor cable construction Detail of connector wiring typical The correct wiring between male and fe...

Page 9: ...trobe as shown with the top hooks resting on the loose Taptite screws Align the lower front screw holes and replace the lower front screws 5 Tighten all screws 6 Rig Atomic 3000 DMX Colors fixture and...

Page 10: ...evices Ensure that all cables are securely fixed and do not present a safety hazard of any sort MPU 02 MPU 08 Power Supplies The MPU 02 and MPU 08 power supplies are specifically designed for use with...

Page 11: ...he power supply For more information on building a data link please refer to the Atomic DMX 3000 user manual Continue daisy chaining the DMX link by connecting the 5 pin DMX thru socket on the power s...

Page 12: ...Atomic Colors fixture 1 to the XLR 4 input on the Atomic Colors fixture 2 5 Repeat step 4 until you have a maximum of four Atomic Colors fixtures connected together 6 Connect the XLR 4 output on the...

Page 13: ...System connection diagram using the MPU 08 power supply For clarity only the Atomic Colors are shown Atomic Colors User Manual Connecting the unit 13...

Page 14: ...ay it is set up and the value of the DMX signal that the unit is receiving Push Button Operation Use the ACTION RECALL button to scroll through the different modes of operation Use the UP or DOWN butt...

Page 15: ...hrough 180 by pressing and holding the ACTION RECALL button then pressing the DOWN button Display Blank The display can be set to auto blackout after short time This is selected through the mode menu...

Page 16: ...the gel string Second DMX Channel Channel Level Dec Channel Level Speed Level Fan Speed 00 61 0 24 Fn4 62 127 25 49 Fn3 128 190 50 74 Fn2 191 255 75 100 Fn1 Fastest Slowest Gel saver GL Toggle the gel...

Page 17: ...d the ACTION RECALL button and press the UP button for 1 second The Factory default settings are Fan Speed Gel Saver Gel Speed Display Light activated Fan Display Flip Fn4 fast GL1 On SP1 normal dP1 O...

Page 18: ...off the gel saving mode Press UP or DOWN once to switch between on 1 and off 0 Note Ensure that the gel is centered by channel DMX value before implementing this mode or the next color may show throu...

Page 19: ...el Level Dec Channel Level Speed Level Fan Speed See notes below 00 61 0 24 Fn4 62 127 25 49 Fn3 128 190 50 74 Fn2 191 255 75 100 Fn1 Fastest Slowest Important notes 1 Please note that over time the g...

Page 20: ...top before attaching it to the anchors New users are recommended to use the manual loading method until they become familiar with the procedure When installing a gel string always start by applying th...

Page 21: ...ft Use small pieces of flat back tape 25mm 1 to secure the gel to the TUR hubs on either side top and bottom 3 Press the DOWN push button to advance the gel string onto the TUR 4 Continue this process...

Page 22: ...Installation of a gel string Atomic Colors User Manual Changing the gel string 22...

Page 23: ...Gel string construction Atomic Colors User Manual Changing the gel string 23...

Page 24: ...lengths are too long No cable return line Check all scroller speed settings Check the cable length and configuration Ensure there is a cable return line in the system Units have dim display indicator...

Page 25: ...ess 0 075 0 125mm 0 003 0 005 in For the best results use gel strings supplied by your dealer Gel frame capacity 2 11 gel frames Construction Housing Steel Finish Black electrostatic powder coat Insta...