Remember that the
addressing operation, is performed with concentrator module in
Off.
Addressing the concentrator will be disabled automatically the stand-alone mode
and reset button P1 functionality. In case of block of the concentrator module, is
possible to reset by switch off the power supply and switch on after a few seconds.
To reactivate the stand-alone mode, turn all the addressing microswitches (1, 2, 3,
4, 5, 6) to OFF witch concentrator switched off.
Installation and Programming Manual V1.2
23
Address
OFF
OFF
OFF
OFF
OFF
OFF
01
OFF
OFF
OFF
OFF
OFF
ON
02
OFF
OFF
OFF
OFF
ON
OFF
03
OFF
OFF
OFF
OFF
ON
ON
04
OFF
OFF
OFF
ON
OFF
OFF
05
OFF
OFF
OFF
ON
OFF
ON
06
OFF
OFF
OFF
ON
ON
OFF
07
OFF
OFF
OFF
ON
ON
ON
08
OFF
OFF
ON
OFF
OFF
OFF
09
OFF
OFF
ON
OFF
OFF
ON
10
OFF
OFF
ON
OFF
ON
OFF
11
OFF
OFF
ON
OFF
ON
ON
12
OFF
OFF
ON
ON
OFF
OFF
13
OFF
OFF
ON
ON
OFF
ON
14
OFF
OFF
ON
ON
ON
OFF
15
OFF
OFF
ON
ON
ON
ON
16
OFF
ON
OFF
OFF
OFF
OFF
17
OFF
ON
OFF
OFF
OFF
ON
18
OFF
ON
OFF
OFF
ON
OFF
19
OFF
ON
OFF
OFF
ON
ON
20
OFF
ON
OFF
ON
OFF
OFF
21
OFF
ON
OFF
ON
OFF
ON
22
OFF
ON
OFF
ON
ON
OFF
23
OFF
ON
OFF
ON
ON
ON
24
OFF
ON
ON
OFF
OFF
OFF
25
OFF
ON
ON
OFF
OFF
ON
26
OFF
ON
ON
OFF
ON
OFF
27
OFF
ON
ON
OFF
ON
ON
28
OFF
ON
ON
ON
OFF
OFF
29
OFF
ON
ON
ON
OFF
ON
30
OFF
ON
ON
ON
ON
OFF
31
OFF
ON
ON
ON
ON
ON
32
ON
OFF
OFF
OFF
OFF
OFF
33
ON
OFF
OFF
OFF
OFF
ON
34
ON
OFF
OFF
OFF
ON
OFF
35
ON
OFF
OFF
OFF
ON
ON
36
ON
OFF
OFF
ON
OFF
OFF
37
ON
OFF
OFF
ON
OFF
ON
38
ON
OFF
OFF
ON
ON
OFF
39
ON
OFF
OFF
ON
ON
ON
40
ON
OFF
ON
OFF
OFF
OFF
41
ON
OFF
ON
OFF
OFF
ON
42
ON
OFF
ON
OFF
ON
OFF
43
ON
OFF
ON
OFF
ON
ON
44
ON
OFF
ON
ON
OFF
OFF
45
ON
OFF
ON
ON
OFF
ON
46
ON
OFF
ON
ON
ON
OFF
47
ON
OFF
ON
ON
ON
ON
48
ON
ON
OFF
OFF
OFF
OFF
Dip-6
Dip-5
Dip-4
Dip-3
Dip-2
Dip-1
00 (not used)